MétaCan
Menu
Back to cohort
Record W3036867233 · doi:10.1093/europace/euaa162.343

915ATP efficacy on terminating ventricular tachycardia by device type, indication, and ventricular median cycle length

2020· article· en· W3036867233 on OpenAlexaff
Takashi Kurita, Laurence D. Sterns, Edward J. Schloss, Angelo Auricchio, Y Zhang, S Li, Albert Meijer, Daniel R. Lexcen

Bibliographic record

VenueEP Europace · 2020
Typearticle
Languageen
FieldMedicine
TopicCardiac Arrhythmias and Treatments
Canadian institutionsRoyal Jubilee Hospital
Fundersnot available
KeywordsMedicineVentricular tachycardiaCardiologyInternal medicineTachycardia

Abstract

fetched live from OpenAlex

Abstract Funding Acknowledgements Medtronic OnBehalf PainFree SST Background Anti-tachycardia Pacing (ATP) is an established therapy that terminates VT without the need for painful ICD shocks. Here we use the data from PainFree SST clinical trial to evaluate the ATP success rate by device type, indication and MCL. Methods Spontaneous episodes that were detected by ICD or CRT-D devices in the VT, fast VT and VF zones were included in the analysis. Episodes successfully terminated by ATP were deemed as having ATP success. Using the GEE method, ATP success rate and its 95% CI were calculated for device types, indications and ventricular MCL. Results Of the 2770 enrolled patients (79% male, average age 65 years), 1699 (61%) were implanted with an ICD and 1071 (39%) with a CRT-D system; 1917 (69%) were reported as primary prevention and 847 (31%) were secondary prevention patients. For all MVT episodes, the ATP success rate was similar between ICD and CRT-D devices (82.3% vs 80.3%, p = 0.74). Patients with secondary prevention had a higher ATP success rate compared to those with primary prevention but the difference was not statistically significant (84.4% vs 76.8%, p = 0.16). Regardless of device type and indication, ATP success rate was significantly higher in the slower VTs (MCL ≥ 320 ms) compared to the faster VTs (MCL ≥ 240 to < 320 ms) (89.2% vs 73.7%, p < 0.0001). Conclusion We found that ATP had a greater than 80% rate of success for terminating ventricular tachycardias overall. Slower VTs was significantly associated with a higher ATP success rate regardless of device type and indication compared to faster VTs. For faster VTs with a MCL ≥ 240 to < 320 ms, the ATP success rate was still successful at terminating VT more than 70% of the time. Table 1. ATP Success Rates - No. of Enrolled Subjects (% of total) No. of Episodes Analyzed for ATP Success (No. of Subjects) GEE-estimated ATP Success Rate (95% CI) P-value* Overall 2770 (100%) 2277 (376) 81.5% (78.4%, 84.2%) - Device Type - - - 0.7440 ICD 1699 (61.3%) 1484 (229) 82.3% (78.3%, 85.6%) - CRT-D 1071 (38.7%) 793 (147) 80.3% (75.0%, 84.6%) - Indication - - - 0.1609 Primary Prevention 1917 (69.2%) 631 (160) 76.8% (71.2%, 81.6%) - Secondary Prevention 847 (30.6%) 1615 (212) 84.4% (80.7%, 87.6%) - Median Cycle Length - - - <0.0001 (>/=) 240 ms and < 320 ms - 861 (257) 73.7% (69.2%, 77.7%) - (>/=) 320 ms - 1416 (209) 89.2% (85.7%, 91.9%) - * Per a GEE main effect model for all episodes where device type, indication and median cycle length were considered.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.547
Threshold uncertainty score0.636

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.261
Teacher spread0.249 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueEP EuropaceSame topicCardiac Arrhythmias and TreatmentsFrench-language works237,207