MétaCan
Menu
Back to cohort
Record W3037020006 · doi:10.1139/cjc-2020-0082

Trace-level quantification of <i>N</i>-nitrosopiperazine in treated wastewater using supported liquid extraction and hydrophilic interaction chromatography mass spectrometry

2020· article· en· W3037020006 on OpenAlexafffundvenue
Anthony Lapointe, Stephanie Gallant, Simon Comtois‐Marotte, Alexandra Fürtös, Karen C. Waldron

Bibliographic record

VenueCanadian Journal of Chemistry · 2020
Typearticle
Languageen
FieldEnvironmental Science
TopicWater Treatment and Disinfection
Canadian institutionsUniversité de Montréal
FundersNatural Sciences and Engineering Research Council of CanadaUniversité de Montréal
KeywordsChemistryHydrophilic interaction chromatographyChromatographyWastewaterMass spectrometryExtraction (chemistry)Sample preparationElectrospraySolid phase extractionDetection limitHigh-performance liquid chromatography

Abstract

fetched live from OpenAlex

Regenerable amine-based solvents used for post-combustion CO2 capture, primarily monoethanolamine and piperazine, are known to undergo degradation and secondary reactions over time forming, amongst other species, N-nitrosamines. These carcinogenic species can eventually make their way from treated wastewater into environmental waters. The United States Environmental Protection Agency (US EPA) recommends that the concentration of N-nitrosamines in surface water not exceed 1.24 μg/L. We have developed a straightforward method to quantify N-nitrosopiperazine in treated wastewater by hydrophilic interaction liquid chromatography – mass spectrometry (HILIC–MS) after sample preparation by supported liquid extraction (SLE). To achieve the best extraction recovery and method limits of quantification (MLOQ), standards were prepared in a high-salt synthetic matrix to mimic the treated wastewater effluent. To further improve the MLOQ, the drying steps after extraction were optimized. HILIC separation of the highly polar analytes was achieved using an ethylene-bridged hybrid amide stationary phase. Detection was achieved using a triple quadrupole mass spectrometer operated in positive electrospray ionisation and multiple reaction monitoring mode, providing a final MLOQ of 0.25 μg/L for N-nitrosopiperazine. Validation of the method was carried out to ensure good confidence in the data obtained for a treated wastewater sample from a post-combustion CO2 capture facility. In addition, N-nitrosopiperazine was quantified with the developed SLE-HILIC–MS method in eight degraded carbon capture samples that had not yet undergone wastewater treatment.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.230
Teacher spread0.206 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2020
Admission routes3
Has abstractyes

Explore more

Same venueCanadian Journal of ChemistrySame topicWater Treatment and DisinfectionFrench-language works237,207