MétaCan
Menu
Back to cohort
Record W3038485807 · doi:10.1109/jtehm.2020.3006416

A Modular Adjustable Transhumeral Prosthetic Socket for Evaluating Myoelectric Control

2020· article· en· W3038485807 on OpenAlexaff
Ben W. Hallworth, James A. Austin, Heather E. Williams, Mayank Rehani, Ahmed W. Shehata, Jacqueline S. Hebert

Bibliographic record

VenueIEEE Journal of Translational Engineering in Health and Medicine · 2020
Typearticle
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsGlenrose Rehabilitation HospitalUniversity of Alberta
FundersScience and Engineering Research CouncilU.S. Department of Defense
KeywordsModular designComputer scienceProcess (computing)Limb lossProsthesisHuman–computer interactionPipeline (software)AmputationSimulationArtificial intelligenceMedicineOperating systemSurgery

Abstract

fetched live from OpenAlex

Novel myoelectric control strategies may yield more robust, capable prostheses which improve quality of life for those affected by upper-limb loss; however, the development and translation of such strategies from an experimental setting towards daily use by persons with limb loss is a slow and costly process. Since prosthesis functionality is highly dependent on the physical interface between the user's prosthetic socket and residual limb, assessment of such controllers under realistic (noisy) environmental conditions, integrated into prosthetic sockets, and with participants with amputation is essential for obtaining representative results. Unfortunately, this step is particularly difficult as participant- and control strategy-specific prosthetic sockets must be custom-designed and manufactured. There is thus a need for a system to reduce these burdens and facilitate this crucial phase of the development pipeline. This study aims to address this gap through the design and assessment of an inexpensive and easy-to-use 3D-printed Modular-Adjustable transhumeral Prosthetic Socket (MAPS). This 3D-printed, open-source socket was developed in consultation with prosthetists and compared with a participant-specific suction socket in a single-participant case-study. We conducted mechanical and functional assessments to ensure that the developed socket enabled similar performance compared to participant-specific sockets. Both socket systems yielded similar results in mechanical and functional assessments, as well as in self-reported user feedback. The MAPS system shows promise as a research tool which catalyzes the development and deployment of novel myoelectric control strategies by better-enabling comprehensive assessment involving participants with amputations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.756
Threshold uncertainty score0.426

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.032
GPT teacher head0.284
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations38
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueIEEE Journal of Translational Engineering in Health and MedicineSame topicMuscle activation and electromyography studiesFrench-language works237,207