MétaCan
Menu
Back to cohort
Record W3039198534 · doi:10.1088/1361-6560/aba317

Fast mixed integer optimization (FMIO) for high dose rate brachytherapy

2020· article· en· W3039198534 on OpenAlexafffund
Majd Antaki, Christopher L. Deufel, Shirin A. Enger

Bibliographic record

VenuePhysics in Medicine and Biology · 2020
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsJewish General HospitalMcGill University Health CentreMcGill University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsInteger programmingMathematical optimizationDwell timeVoxelAlgorithmMathematicsInteger (computer science)Computer scienceArtificial intelligence

Abstract

fetched live from OpenAlex

Abstract The purpose of this work was to develop an efficient quadratic mixed integer programming algorithm for high dose rate (HDR) brachytherapy treatment planning problems and integrate the algorithm into an open-source Monte Carlo based treatment planning software, RapidBrachyMCTPS. The mixed-integer algorithm yields a globally optimum solution to the dose volume histogram (DVH) based problem and, unlike other methods, is not susceptible to local minimum trapping. A hybrid linear-quadratic penalty model coupled to a mixed integer programming model was used to optimize treatment plans for 10 prostate cancer patients. Dose distributions for each dwell position were calculated with RapidBrachyMCTPS with type A uncertainties less than 0.2% in voxels within the planning target volume (PTV). The optimization process was divided into two parts. First, the data was preprocessed, in which the problem size was reduced by eliminating voxels that had negligible impact on the solution (e.g. far from the dwell position). Second, the best combination of dwell times to obtain a plan with the highest score was found. The dwell positions and dose volume constraints were used as input to a commercial mixed integer optimizer (Gurobi Optimization, Inc.). A penalty-based criterion was adopted for the scoring. The voxel-reduction technique successfully reduced the problem size by an average of 91%, without loss of quality. The preprocessing of the optimization process required on average 4 s and solving for the global maximum required on average 33 s. The total optimization time averaged 37 s, which is a substantial improvement over the ∼15 min optimization time reported in published literature. The plan quality was evaluated by evaluating dose volume metrics, including PTV D 90 , rectum and bladder D 1 cc and urethra D 0.1 cc . In conclusion, fast mixed integer optimization is an order of magnitude faster than current mixed-integer approaches for solving HDR brachytherapy treatment planning problems with DVH based metrics.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.005
Threshold uncertainty score0.017

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.091
GPT teacher head0.374
Teacher spread0.282 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2020
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207