Energy Flexibility Assessment of a Zone with Radiant Floor Heating System by Means of Experimental Measurements
Bibliographic record
Abstract
This article investigates the potential energy flexibility of a thermal zone that contains a hydronic radiant floor heating system embedded in a concrete slab. The energy flexibility of the zone is quantified from experimental measurements for a specific zone air set point change. The experiment was carried out in an experimental perimeter zone test cell (PZTC) designed to simulate the conditions of an office space near a window which has a radiant floor heating system. The PZTC is located inside a controlled environmental chamber (EC). The EC provides the desired exterior conditions. The temperature inside the PZTC is controlled with a thermostat that adjusts the heating power delivered from the hydronic pipes to the slab. It was observed that modulating the zone air temperature setpoint results in significant changes in the heating load, and thus providing a certain amount of energy flexibility. Application of the quantified energy flexibility along with applicable strategies in response to a specific price signal profile are discussed.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".