Localization of Green Fluorescent Protein Absorbance by Energy Filtered Transmission Electron Microscopy
Bibliographic record
Abstract
Abstract Energy filtered transmission electron microscopy has the potential to provide high resolution, spatially resolved, atomic and chemical information. However, aberrations generated by the electron spectrometer blur the energy resolution and limit the atomic or molecular distributions that can be studied. Energy absorptions corresponding to the visible light range fall below an energy loss of 5 eV. The selection of electrons that have lost an amount of energy corresponding to chromophore absorption by the sample thus requires a spectrometer with a high energy resolution over the full image plane. A corrected prism-mirror-prism filter that has a resolution of 1.1 eV, sufficient to select these low energy loss electrons, was developed and installed by us in a Zeiss EM902. Its imaging capability was verified for a number of different chromophores. The chromophore currently under study is that of the green fluorescent protein (GFP).
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".