MétaCan
Menu
Back to cohort
Record W3041989323 · doi:10.1111/pace.14005

Minimalistic strategy for coronary sinus lead implant: A single tool capable of electrophysiological mapping, pressure measurement, and angiography

2020· article· en· W3041989323 on OpenAlexaff
Rahul Samanta, Ben Ng, Andrew C.T. Ha, Abhishek Bhaskaran, Mahmoud Bokhari, Krishnakumar Nair, Kumaraswamy Nanthakumar

Bibliographic record

VenuePacing and Clinical Electrophysiology · 2020
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsToronto General HospitalUniversity Health Network
Fundersnot available
KeywordsMedicineLead (geology)Coronary sinusIntracardiac injectionCatheterCardiac resynchronization therapyImplantAngiographyCardiologyCardiac catheterizationCoronary angiographyAngioplastyRadiologyInternal medicineSurgeryEjection fractionHeart failure

Abstract

fetched live from OpenAlex

BACKGROUND: Left ventricular (LV) lead implantation for cardiac resynchronization therapy (CRT) may be confounded by contrast load during attempted cannulation and lead dislodgement during guiding catheter splitting. An LV lead implant system with a steerable single catheter that completely avoids the use of guiding catheters when needed, acquires atrioventricular electrograms, measures intracardiac pressures, permits CS angiography, and has the ability to direct a coronary angioplasty wire that will lead the final delivery of LV lead into a CS tributary, may help limit contrast use and avoid lead dislodgement at CS guide sheath removal. METHODS AND RESULTS: In this article as a proof of concept, we describe the use of this minimalist technique as a first line approach in six patients who had standard indications for CRT. The LV lead was successfully implanted in a target vein in all patients without acute complications. Contrast was not used in half the group and the LV lead was successfully implanted without guiding catheter in four patients. The implantation technique evolved through the series and in the final patient, no guiding sheath or contrast was used. Postimplant lead positions on chest X-ray and lead parameters were stable in all patients at follow-up. CONCLUSION: In proof of concept paper, we describe a technique of LV lead implantation potentially without the use of contrast and standard CS guiding catheters. Once familiar, this approach may provide a less complicated strategy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.104
GPT teacher head0.327
Teacher spread0.223 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2020
Admission routes1
Has abstractyes

Explore more

Same venuePacing and Clinical ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207