MétaCan
Menu
Back to cohort
Record W3042736962 · doi:10.1088/1361-6579/aba6a1

A portable device with low-power consumption for monitoring mouse vital signs during <i>in vivo</i> photoacoustic imaging and photothermal therapy

2020· article· en· W3042736962 on OpenAlexaff
Duc Tri Phan, Thi Tuong Vy Phan, Ngoc Thang Bui, Sumin Park, Jaeyeop Choi, Junghwan Oh

Bibliographic record

VenuePhysiological Measurement · 2020
Typearticle
Languageen
FieldEngineering
TopicPhotoacoustic and Ultrasonic Imaging
Canadian institutionsTellabs (Canada)
FundersInstitute for Information and Communications Technology PromotionMinistry of Science and ICT, South KoreaPukyong National University
KeywordsVital signsPhotothermal therapyPower consumptionPhotoacoustic imaging in biomedicineBiomedical engineeringIn vivoOxygen saturationPhotoplethysmogramMaterials scienceOxygenMedicineChemistryNanotechnologyAnesthesiaBiologyComputer sciencePower (physics)

Abstract

fetched live from OpenAlex

Abstract Objective : The aim of this study was to monitor the physiological changes and cytotoxic effects of exogenous contrast agents during photoacoustic imaging (PAI) and photothermal therapy (PTT). In this paper, a low-power telemetric device for mouse vital signs monitoring was designed and demonstrated. Approach : The power consumption was optimized through hardware and software co-design with a 17% increased operating time compared with typical operation. To demonstrate the feasibility of the monitoring device, PAI and PTT experiments with chitosan-polypyrrole nanocomposites (CS-PPy NCs) as exogenous contrast agents were conducted. Herein, the physiological variation in groups of mice with different CS-PPy NC concentrations was observed and analyzed. Main results : The experimental results indicated the influence of CS-PPy NCs and anesthesia on mouse vital signs in PAI and PTT. Additionally, the association between core temperature, heart rate, and saturation of peripheral oxygen (SpO 2 ) during PAI and PTT was shown. The strong near-infrared absorbance of exogenous contrast agents could account for the increase in mouse core temperature and tumor temperature in this study. Furthermore, high cross-correlation values between core temperature, heart rate, and SpO 2 were demonstrated to explain the fluctuation of mouse vital signs during PAI and PTT. Significance : A design of a vital signs monitoring device, with low power consumption, was introduced in this study. A high cross correlation coefficient of mouse vital signs and the effects of CS-PPy NCs were observed, which explained the mouse physiological variation during the PAI and PTT experiments.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.025
Threshold uncertainty score0.898

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.224
Teacher spread0.189 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2020
Admission routes1
Has abstractyes

Explore more

Same venuePhysiological MeasurementSame topicPhotoacoustic and Ultrasonic ImagingFrench-language works237,207