Sutureless and rapid deployment implantation in bicuspid aortic valve: results from the sutureless and rapid-deployment aortic valve replacement international registry
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
BACKGROUND: Benefits of sutureless and rapid deployment (SURD) bioprostheses in bicuspid aortic valves (BAV) are controversial. The aim of this study is to report the outcomes of patients undergoing aortic valve replacement (AVR) for BAV from the Sutureless and Rapid-Deployment Aortic Valve Replacement International Registry (SURD-IR). METHODS: Of the 4,636 patients who received primary isolated SURD-AVR between 2007 and 2018, 191 (4.1%) BAV patients underwent AVR with SURD valve. RESULTS: Overall 30-day mortality was 1.6%. The Intuity valve was implanted in 53.9% of cases, whereas the Perceval was implanted in 46.1%. Rate of stroke for isolated AVR was 4.2%. No case of endocarditis, thromboembolism, myocardial infarction, valve dislocation or structural valve deterioration was reported in the early phase. Rate of pacemaker implantation and moderate-severe aortic regurgitation (AR) were 7.9% and 3.7%, respectively. CONCLUSIONS: BAV is not considered a contraindication for the implantation of SURD valves. However, detailed information of aortic root geometry as well as the knowledge of some technical considerations are mandatory for a good outcome.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it