MétaCan
Menu
Back to cohort
Record W3044114430 · doi:10.1002/mp.14405

Geometrically variable three‐dimensional ultrasound for mechanically assisted image‐guided therapy of focal liver cancer tumors

2020· article· en· W3044114430 on OpenAlexafffund
Derek J. Gillies, Jeffery Bax, Kevin Barker, Lori Gardi, Nirmal Kakani, Aaron Fenster

Bibliographic record

VenueMedical Physics · 2020
Typearticle
Languageen
FieldEngineering
TopicSoft Robotics and Applications
Canadian institutionsWestern University
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health Research
KeywordsImaging phantomScannerAblationWorkflow3D ultrasoundMedical imagingMedicineImage-guided surgeryArtificial intelligenceComputer visionUltrasoundMedical physicsComputer scienceBiomedical engineeringRadiology

Abstract

fetched live from OpenAlex

PURPOSE: Image-guided focal ablation procedures are first-line therapy options in the treatment of liver cancer tumors that provide advantageous reductions in patient recovery times and complication rates relative to open surgery. However, extensive physician training is required and image guidance variabilities during freehand therapy applicator placement limit the sufficiency of ablation volumes and the overall potential of these procedures. We propose the use of three-dimensional ultrasound (3D US) to provide guidance and localization of therapy applicators, augmenting current ablation therapies without the need for specialized procedure suites. We have developed a novel scanning mechanism for geometrically variable 3D US images, a mechanical tracking system, and a needle applicator insertion workflow using a custom needle applicator guide for targeted image-guided procedures. METHODS: A three-motor scanner was designed to use any commercially available US probe to generate accurate, consistent, and geometrically variable 3D US images. The designed scanner was mounted on a counterbalanced stabilizing and mechanical tracking system for determining the US probe orientation, which was assessed using optical tracking. Further exploiting the utility of the motorized scanner, an image-guidance workflow was developed that moved the probe to any identified target within an acquired 3D US image. The complete 3D US guidance system was used to perform mock targeted interventional procedures on a phantom by selecting a target in a 3D US image, navigating to the target, and performing needle insertion using a custom 3D-printed needle applicator guide. Registered postinsertion 3D US images and cone-beam computed tomography (CBCT) images were used to evaluate tip targeting errors when using the motors, tracking system, or mixed navigation approaches. Two 3D US image geometries were investigated to assess the accuracy of a small-footprint tilt approach and a large field-of-view hybrid approach for a total of 48 targeted needle insertions. 3D US image quality was evaluated in a healthy volunteer and compared to a commercially available matrix array US probe. RESULTS: A mean positioning error of 1.85 ± 1.33 mm was observed when performing compound joint manipulations with the mechanical tracking system. A combined approach for navigation that incorporated the motorized movement and the in-plane tracking system corrections performed the best with a mean tip error of 3.77 ± 2.27 mm and 4.27 ± 2.47 mm based on 3D US and CBCT images, respectively. No significant differences were observed between hybrid and tilt image acquisition geometries with all mean registration errors ≤1.2 mm. 3D US volunteer images resulted in clear reconstruction of clinically relevant anatomy. CONCLUSIONS: A mechanically tracked system with geometrically variable 3D US provides a utility that enables enhanced applicator guidance, placement verification, and improved clinical workflow during focal liver tumor ablation procedures. Evaluations of the tracking accuracy, targeting capabilities, and clinical imaging feasibility of the proposed 3D US system, provided evidence for clinical translation. This system could provide a workflow for improving applicator placement and reducing local cancer recurrence during interventional procedures treating liver cancer and has the potential to be expanded to other abdominal interventions and procedures.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.267
Teacher spread0.230 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicSoft Robotics and ApplicationsFrench-language works237,207