MétaCan
Menu
Back to cohort
Record W3045966900 · doi:10.1111/trf.15934

Comparison of the platelet activation status of single‐donor platelets obtained with two different cell separator technologies

2020· article· en· W3045966900 on OpenAlexaff
Daniel Millar, Chelsea Hayes, Jessica Jones, Ellen Klapper, Joel N. Kniep, Hung S. Luu, Daniel K. Noland, Laura Petitti, Jessica Poisson, Erik Spaepen, Zhan Ye, Elisabeth Maurer‐Spurej

Bibliographic record

VenueTransfusion · 2020
Typearticle
Languageen
FieldMedicine
TopicBlood transfusion and management
Canadian institutionsCanadian Blood ServicesQuest University CanadaUniversity of British Columbia
Fundersnot available
KeywordsPlateletApheresisPlatelet activationChemistryAndrologyMedicineImmunology

Abstract

fetched live from OpenAlex

BACKGROUND: The microparticle content (MP%) of apheresis platelets-a marker of platelet activation-is influenced by donor factors and by external stressors during collection and storage. This study assessed the impact of apheresis technology and other factors on the activation status (MP%) of single-donor apheresis platelets. STUDY DESIGN AND METHODS: Data from six US hospitals that screened platelets by measuring MP% through dynamic light scattering (ThromboLUX) were retrospectively analyzed. Relative risks (RRs) were derived from univariate and multivariable regression models, with activation rate (MP% ≥15% for plasma-stored platelets; ≥10% for platelet additive solution [PAS]-stored platelets) and MP% as outcomes. Apheresis platform (Trima Accel vs Amicus), storage medium (plasma vs PAS), pathogen reduction, storage time, and testing location were used as predictors. RESULTS: Data were obtained from 7511 platelet units collected using Trima (from 16 suppliers, all stored in plasma, 20.0% were pathogen-reduced) and 2456 collected using Amicus (from four different collection facilities of one supplier, 65.0% plasma-stored, 35.0% PAS-stored, none pathogen-reduced). Overall, 30.0% of Trima platelets were activated compared to 45.6% of Amicus platelets (P < .0001). Multivariable analysis identified apheresis platform as significantly associated with platelet activation, with a lower activation rate for Trima than Amicus (RR: 0.641, 95% confidence interval [CI]: 0.578; 0.711, P < .0001) and a 6.901% (95% CI: 5.926; 7.876, P < .0001) absolute reduction in MP%, when adjusting for the other variables. CONCLUSION: Trima-collected platelets were significantly less likely to be activated than Amicus-collected platelets, irrespective of the storage medium, the use of pathogen reduction, storage time, and testing site.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.015
Threshold uncertainty score0.425

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.275
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueTransfusionSame topicBlood transfusion and managementFrench-language works237,207