MétaCan
Menu
Back to cohort
Record W3045992298 · doi:10.1002/lary.29014

Recommended Personal Protective Equipment for Cochlear Implant and Other Mastoid Surgery During the <scp>COVID</scp>‐19 Era

2020· article· en· W3045992298 on OpenAlexfundno aff
Rachael Lawrence, Gerard M. O’Donoghue, Pádraig T. Kitterick, Kevin O’Donoghue, Richard Hague, Laura E. Mitchell, Zoe Lycett‐Ranson, Douglas E. H. Hartley

Bibliographic record

VenueThe Laryngoscope · 2020
Typearticle
Languageen
FieldMedicine
TopicEar Surgery and Otitis Media
Canadian institutionsnot available
FundersNIHR Nottingham Biomedical Research CentreMedical Research CouncilNottingham University Hospitals NHS TrustUniversity of NottinghamEngineering and Physical Sciences Research CouncilNational Institute for Health and Care ResearchMedical Research Council CanadaDepartment of Health and Social Care
KeywordsCoronavirus disease 2019 (COVID-19)Cochlear implantPersonal protective equipment2019-20 coronavirus outbreakSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2)MedicineAudiologyDentistryInternal medicineVirology

Abstract

fetched live from OpenAlex

OBJECTIVES/HYPOTHESIS: The overall aim of this study was to evaluate personal protective equipment (PPE) that may facilitate the safe recommencement of cochlear implantation in the COVID-19 era, with the broader goal of minimizing the period of auditory deprivation in prelingually deaf children and reducing the risk of cochlear ossification in individuals following meningitis. METHODS: The study design comprised 1) an objective assessment of mastoid drilling-induced droplet spread conducted during simulated cochlear implant (CI) surgery and its mitigation via the use of a protective drape tent and 2) an evaluation of three PPE configurations by otologists while performing mastoid drilling on ex vivo temporal bones. The various PPE solutions were assessed in terms of their impact on communication, vital physiological parameters, visual acuity and fields, and acceptability to surgeons using a systematic risk-based approach. RESULTS: Droplet spread during simulated CI surgery extended over 2 m, a distance greater than previously reported. A drape tent significantly reduced droplet spread. The ensemble of a half-face mask and safety spoggles (foam lined safety goggles) had consistently superior performance across all aspects of clinical usability. All other PPE options were found to substantially restrict the visual field, making them unsafe for microsurgery. CONCLUSIONS: The results of this preclinical study indicate that the most viable solution to enable the safe conduct of CI and other mastoid surgery is a combination of a filtering facepiece (FFP3) mask or half-face respirator with safety spoggles as PPE. Prescription spoggles are an option for surgeons who need to wear corrective glasses to operate. A drape tent reduces droplet spread. A multicenter clinical trial to evaluate the effectiveness of PPE should be the next step toward safely performing CI surgery during the COVID-19 era. LEVEL OF EVIDENCE: 4 Laryngoscope, 130:2693-2699, 2020.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.348
Threshold uncertainty score0.447

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.042
GPT teacher head0.268
Teacher spread0.226 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueThe LaryngoscopeSame topicEar Surgery and Otitis MediaFrench-language works237,207