MétaCan
Menu
Back to cohort
Record W3046744919 · doi:10.1007/s00167-020-06185-0

Tibial tray cementation is not necessary for knee revision with titanium metaphyseal sleeves: a mid‐term prospective study in AORI 2B defects

2020· article· en· W3046744919 on OpenAlexaboutno aff
L.J. Floría-Arnal, A.M. Gómez-Blasco, Adrián Roche‐Albero, J. J. Panisello-Sebastiá, Adrián Martín Martínez, Carlos Martín Hernández

Bibliographic record

VenueKnee Surgery Sports Traumatology Arthroscopy · 2020
Typearticle
Languageen
FieldMedicine
TopicTotal Knee Arthroplasty Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineFixation (population genetics)Prospective cohort studyRadiographySurgeryTibiaFemurWOMACOrthodonticsDentistryOsteoarthritisPopulation

Abstract

fetched live from OpenAlex

PURPOSE: Metaphyseal fixation with porous titanium sleeves in revision knee surgery provides mechanical support to the implant, promotes biological fixation, and has shown satisfactory short- and mid-term results. Cement is commonly used to fix the tibial tray to the epiphyseal area. The objective of this study is to determine whether cement should be used to achieve fixation of the tibial tray with the hypothesis that metaphyseal sleeves would provide enough axial and rotational stability making cementation unnecessary. MATERIAL AND METHODS: Prospective study of 60 patients undergoing knee replacement surgery with metaphyseal sleeves in type 2B defects in femur and tibia. Patients were divided into two groups according to the use of cement on the tibial component. Analysis included the American Knee Society Score (KSS) knee and functional scales, the Western Ontario and McMaster Universities (WOMAC) index, the Short Form 12 (SF-12) health survey, and radiographic assessment with a maximum follow-up of 5 years. RESULTS: No statistically significant differences were found between the two groups in any of the parameters assessed. CONCLUSION: Metaphyseal sleeves showed a 100% survivorship at five years of followup. There were no differences in clinical and radiographic outcomes at five years of follow-up depending on whether or not cement was used for tibial platform fixation. Cementation of the tibial tray would therefore not be required to achieve satisfactory mid-term results. LEVEL OF EVIDENCE: Level II: prospective cohort study. Therapeutic.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.297
Teacher spread0.267 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueKnee Surgery Sports Traumatology ArthroscopySame topicTotal Knee Arthroplasty OutcomesFrench-language works237,207