MétaCan
Menu
Back to cohort
Record W3047288244 · doi:10.25270/jic/20.00037

Transradial Crossover Balloon Occlusion Technique for Primary Access Hemostasis During Transcatheter Aortic Valve Replacement: Initial Experience With the Oceanus 140 cm and 200 cm Balloon Catheters

2020· article· en· W3047288244 on OpenAlexaff
Lucía Junquera, Victòria Vilalta, Ramiro Trillo, Manel Sabaté, Azeem Latib, Luis Nombela‐Franco, César Morı́s, Bruno García del Blanco, Mariano Larman, José M. de la Torre Hernández, Andrés Íñiguez, Ignacio J. Amat‐Santos, Eduard Fernández‐Nofrerías, Ander Regueiro, Antonio Colombo, Georgios Tzanis, Pilar Jiménez‐Quevedo, Isabel Perez-Serranos, Marta Duran-Priu, Lluís Duocastella, Jean-Michel Paradis, Josep Rodés Cabau

Bibliographic record

Venue˜The œJournal of invasive cardiology/˜The œjournal of invasive cardiology · 2020
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsUniversité Laval
Fundersnot available
KeywordsHemostasisBalloonMedicineCrossoverOcclusionSurgeryComputer science

Abstract

fetched live from OpenAlex

OBJECTIVES: The crossover balloon occlusion technique (CBOT) facilitates primary access hemostasis in patients undergoing transfemoral transcatheter aortic valve replacement (TAVR). The CBOT is usually performed through the contralateral femoral artery. The aim of this study was to evaluate, in patients undergoing TAVR, the safety and feasibility of transradial CBOT using the new Oceanus balloon dilatation catheter (iVascular). METHODS: This multicenter study included 104 patients (mean age, 81 ± 7 years; 43% women) undergoing transfemoral TAVR. A modified CBOT through the radial artery was performed in all patients with the Oceanus balloon catheter. Data regarding transradial CBOT, balloon performance, vascular complications, and 30-day clinical events were recorded. RESULTS: Up to 21% of patients had a height >170 cm and 17% presented with severe aortic/iliofemoral tortuosity. The transradial CBOT (left radial 74%, right radial 26%) was performed using either the 140 cm Oceanus (37.5%) or the 200 cm Oceanus (62.5%) balloon catheter. The balloon reached the femoral artery in all patients, and balloon inflation achieved an appropriate vessel closure in 98%. There were no complications related to the balloon catheter, and only 1 patient (1.0%) suffered a minor vascular complication related to the secondary radial access. The 30-day rates of primary access major vascular complications and death were 3.8% and 1.9%, respectively. CONCLUSION: In patients undergoing transfemoral TAVR, transradial CBOT with the Oceanus balloon dilatation catheter was feasible and safe. A balloon length up to 200 cm allowed the use of this technique (from right or left radial access) in all patients regardless of patient height or the presence of a challenging vascular anatomy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.160
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0020.004
Bibliometrics0.0000.000
Science and technology studies0.0010.002
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.301
Teacher spread0.279 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2020
Admission routes1
Has abstractyes

Explore more

Same venue˜The œJournal of invasive cardiology/˜The œjournal of invasive cardiologySame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207