MétaCan
Menu
Back to cohort
Record W3047858065 · doi:10.1097/opx.0000000000001553

Lipid Analysis on Block Copolymer–containing Packaging Solution and Lens Care Regimens: A Randomized Clinical Trial

2020· article· en· W3047858065 on OpenAlexaff
Amanda Shows, Rachel L. Redfern, Wolfgang Sickenberger, Jennifer Swingle Fogt, Marc Schulze, Christopher Lievens, Loretta Szczotka‐Flynn, Štefan Schwarz, Anna A. Tichenor, Sebastian Marx, Jessie Lemp-Hull

Bibliographic record

VenueOptometry and Vision Science · 2020
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsSilicone hydrogelLens (geology)Randomized controlled trialMedicineContact lensEye careOphthalmologySurgeryOptometryOptics

Abstract

fetched live from OpenAlex

SIGNIFICANCE: Lotrafilcon B lenses packaged in and cared for with block copolymer-containing (polyoxyethylene-polyoxybutylene; EOBO) lens care solutions resulted in lower cholesterol extraction than each of the habitual silicone hydrogel lens/multipurpose solution (MPS) regimens tested. PURPOSE: This study aimed to compare the extracted cholesterol of lotrafilcon B lenses packaged in and cared for with EOBO-containing lens care solutions with the extracted cholesterol of habitual silicone hydrogel lenses cared for with MPS not containing EOBO. METHODS: In this prospective, randomized, observer-masked parallel study, habitual wearers of senofilcon C, senofilcon A, comfilcon A, and samfilcon A contact lenses using a non-EOBO MPS were randomized 1:1 to lotrafilcon B lenses packaged in and cared for with EOBO-containing solutions or to their habitual lenses and MPS. Subjects randomized to lotrafilcon B were further randomized to one of two EOBO-containing lens care solutions, OPTI-FREE PUREMOIST or CLEAR CARE PLUS with HydraGlyde (Alcon Laboratories, Inc., Fort Worth, TX). A subset of right eye lenses was collected after wear, and total cholesterol was extracted and measured using a fluorometric enzymatic assay. RESULTS: Of 143 lenses analyzed, 95 were from subjects randomized to their habitual lenses/MPS and 48 to lotrafilcon B + EOBO lenses plus CLEAR CARE PLUS with HydraGlyde or OPTI-FREE PUREMOIST. The mean amounts of cholesterol extracted from lotrafilcon B + EOBO lenses cared for with CLEAR CARE PLUS with HydraGlyde (0.28 ± 0.18 μg/lens) and OPTI-FREE PUREMOIST (0.28 ± 0.48 μg/lens) were significantly lower than those extracted from senofilcon C (4.18 ± 3.25 μg/lens), senofilcon A (2.19 ± 2.69 μg/lens), comfilcon A (2.17 ± 1.47 μg/lens), and samfilcon A (2.07 ± 1.48 μg/lens) lenses used with MPS (P < .0001 each). CONCLUSIONS: Cholesterol sorption was significantly lower in wearers of lotrafilcon B lenses cared for with polyoxyethylene-polyoxybutylene-containing lens care solutions than in users of habitual silicone hydrogel lenses cared for with non-polyoxyethylene-polyoxybutylene MPS.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.225
Threshold uncertainty score0.446

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.040
GPT teacher head0.439
Teacher spread0.399 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueOptometry and Vision ScienceSame topicOcular Surface and Contact LensFrench-language works237,207