MétaCan
Menu
Back to cohort
Record W3047870950 · doi:10.1177/0021955x20948556

Enhancing the accuracy and efficiency of characterizing polymeric cellular structures using 3D-based computed tomography

2020· article· en· W3047870950 on OpenAlexaff
Pedram Karimipour-Fard, Ibrahim Naeem, Atef Mohany, Remon Pop‐Iliev, Ghaus Rizvi

Bibliographic record

VenueJournal of Cellular Plastics · 2020
Typearticle
Languageen
FieldMaterials Science
TopicPolymer Foaming and Composites
Canadian institutionsOntario Tech University
Fundersnot available
KeywordsPorosityMaterials scienceContext (archaeology)Scanning electron microscopeTomographyComputed tomographyPolymerVisualizationBiological systemBiomedical engineeringMicroscopyComposite materialComputer scienceArtificial intelligenceOptics

Abstract

fetched live from OpenAlex

Characterizing the morphology of polymeric foams is crucial for determining their practical applicability. The internal cellular structure of polymeric foams is typically analyzed by 2 D imaging techniques, such as Scanning Electron Microscopy (SEM) and optical microscopy. The problem with these techniques is that their tests are tedious, destructive, and the accuracy of the obtained results is questionable. The objective of this paper is to establish and experimentally verify an efficient 3- dimensional (3 D) Microcomputed-tomography based methodology for reliably estimating and characterizing each of the phases commonly present in multiple types of polymeric foam samples, such as the open, the closed, and the solid phase. A comparative study was carried out between morphology data obtained from 2-dimensional (2 D) analysis and those obtained from 3 D analysis to investigate the reliability of the 2 D analysis results. In this context, the experimental results revealed that by using a 2 D method the open porosity was underestimated at the expense of closed porosity, which in turn was overestimated, while the total porosity was not impacted. Also, visualization of the internal structure of polymer foams by using Micro-CT provides details about the 3 D space which cannot be obtained from SEM images. The analysis of foamed specimen demonstrated that the polymeric foam phases extracted from Micro-CT images were in agreement with the experimentally measured values of total porosity of the samples. In an effort to reduce computational requirements, the effects of reducing data size on the accuracy of results has also been studied by averaging image pixels in 3 D space and the results were compared for multiple types of foam structures. This method reduced the processing time considerably, and yielded comparable porosity values. However, the number of detected pores were lowered due to the inability of this method to detect very small cells after 3 D averaging of image pixels.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.163
Threshold uncertainty score0.497

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.217
Teacher spread0.203 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Cellular PlasticsSame topicPolymer Foaming and CompositesFrench-language works237,207