MétaCan
Menu
← Back to cohort

E-232 Mid-term results of aneurysm treatment with the new surpass evolve flow diverter: a multicenter experience

2020· article· en· W3048050767 on OpenAlexaff
Emanuele Orrù, Hal Rice, Laetitia de Villiers, Ajay K. Wakhloo, Ghim Song Chia, Ayman Qureshi, Timo Krings, Vítor Mendes Pereira

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldMedicine
TopicIntracranial Aneurysms: Treatment and Complications
Canadian institutionsToronto Western Hospital
Fundersnot available
KeywordsMedicineAneurysmNeurovascular bundleFlow diverterSurgeryEmbolizationEndovascular treatmentRadiology

Abstract

fetched live from OpenAlex

Purpose Flow diverters have become a safe and well-accepted treatment option for intracranial aneurysms of most sizes in the anterior and posterior circulation. Surpass Evolve (SE, Stryker Neurovascular, Kalamazoo, Michigan, USA) is a new flow diverter that is available in large diameters (2.5–5 mm) and long lengths (12–40 mm), with high radial force and a high in-vitro flow diverting effect irrespective of the parent vessel tortuosity. This is secondary to a consistency in mesh density (15–30 pores/mm2) and a high number of wires (48–64, depending on the device length). SE can be deployed through an 0.027’ microcatheter, allowing easy navigation within tortuous anatomies. We describe device characteristics and mid-term results in the first patients treated with the SE for intracranial aneurysms. Materials and Methods We included in this report all patients that underwent aneurysm embolization with the SE at two different institutions. Patients’ data was prospectively collected in two databases and reviewed retrospectively. We included adult patients harboring non-ruptured saccular or fusiform intracranial aneurysms with a wide neck (>4 mm) located in the anterior or posterior circulation. Standard dual anti-platelet therapy was started 5 days pre-procedure and continued for at least 6 months. Neurological complications were classified as intra-procedural, early or delayed if they arose within 1, 30 or more than 30 days from treatment, respectively. Neurological complications were considered minor and major if resulting in transient or permanent neurological morbidity, respectively. Clinical status at discharge and follow up was assessed by independent neurologists or neurosurgeons and imaging included MRI angiography (MRA), CT angiography (CTA) and DSA, depending on the institution. Results The study included 28 patients (23 females, 82%; age range: 36–86, median age: 56) treated between April and November 2019, harboring 29 aneurysms. Twenty-eight aneurysms were saccular and in the anterior circulation. The majority of aneurysms were <12 mm in diameter (18/29, 62%), 8/29 (28%) were large (<25 mm), 2/29 (7%) were giant (>25 mm) and one was fusiform and partially thrombosed (3%). The SE was delivered in all cases via a tri-axial approach with an intermediate catheter and a 0.027’ microcatheter for implant delivery. This low-profile catheter allowed delivery of the implant through the trans-radial route. Thirty-two implants were used (4 in the patient with the fusiform aneurysm) with an average of 1.1 stents/patient. There were no intra-procedural complications. Median clinical and imaging follow up time was 6 months (range: 2–6 months). There were no deaths. Three patients (3/28, 11%) had early minor neurological complications. There was one (4%) early major neurological complication in a patient with a hemispheric stroke on post-op day 4. Two patients had minor delayed neurological complications (2/28, 7%). Complete thrombosis was seen in 16/29 aneurysms (55%, most of those imaged at 6 months), while partial thrombosis was seen in 12/29 aneurysms (41%). Covered side branches were patent in all patient but the one who experienced the stroke. Conclusion The SE shows excellent navigability while keeping a high flow-diverting effect. Mid-term clinico-radiological results show good efficacy and acceptable safety of the implant. Disclosures E. Orru: None. H. Rice: 2; C; Medtronic, Stryker, Philips, Penumbra, Microvention. L. De Villiers: None. A. Wakhloo: 1; C; Philips. 2; C; Stryker, Phenox. 3; C; SCENT trial. 4; C; InNeuroCo, EpiEP, Neural Analytics, Rist, Analytics 4 Life, ThrombX. G. Song Chia: None. A. Qureshi: None. T. Krings: 2; C; Stryker, Medtronic, Penumbra. 4; C; Marblehead Inc. V. Pereira: 1; C; Philips Healthcare. 2; C; Stryker, Balt, Cerenovous, Medtronic.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.260
Teacher spread0.232 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2020
Admission routes1
Has abstractyes

Explore more

Same topicIntracranial Aneurysms: Treatment and Complications→French-language works237,207→