MétaCan
Menu
Back to cohort
Record W3048968099 · doi:10.1016/j.jhin.2020.08.005

Efficacy and safety of disinfectants for decontamination of N95 and SN95 filtering facepiece respirators: a systematic review

2020· review· en· W3048968099 on OpenAlexafffund
Katie O’Hearn, Shira Gertsman, Richard Webster, Anne Tsampalieros, R. Ng, Jess Gibson, Margaret Sampson, Lindsey Sikora, James Dayre McNally

Bibliographic record

VenueJournal of Hospital Infection · 2020
Typereview
Languageen
FieldMedicine
TopicInfection Control and Ventilation
Canadian institutionsUniversity of OttawaChildren's Hospital of Eastern Ontario
FundersOntario Ministry of Health and Long-Term Care
KeywordsHuman decontaminationRespiratorMedicineSodium hypochloriteCoronavirus disease 2019 (COVID-19)DisinfectantInfectious disease (medical specialty)Internal medicine

Abstract

fetched live from OpenAlex

Background Decontaminating and reusing filtering facepiece respirators (FFRs) for healthcare workers is a potential solution to address inadequate FFR supply during a global pandemic. Aim The objective of this review was to synthesize existing data on the effectiveness and safety of using chemical disinfectants to decontaminate N95 FFRs. Methods A systematic review was conducted on disinfectants to decontaminate N95 FFRs using Embase, Medline, Global Health, Google Scholar, WHO feed, and MedRxiv. Two reviewers independently determined study eligibility and extracted predefined data fields. Original research reporting on N95 FFR function, decontamination, safety, or FFR fit following decontamination with a disinfectant was included. Findings and Conclusion A single cycle of vaporized hydrogen peroxide (H 2 O 2 ) successfully removes viral pathogens without affecting airflow resistance or fit, and maintains an initial filter penetration of <5%, with little change in FFR appearance. Residual hydrogen peroxide levels following decontamination were within safe limits. More than one decontamination cycle of vaporized H 2 O 2 may be possible but further information is required on how multiple cycles would affect FFR fit in a real-world setting before the upper limit can be established. Although immersion in liquid H 2 O 2 does not appear to adversely affect FFR function, there is no available data on its ability to remove infectious pathogens from FFRs or its impact on FFR fit. Sodium hypochlorite, ethanol, isopropyl alcohol, and ethylene oxide are not recommended due to safety concerns or negative effects on FFR function.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.007
metaresearch head score (Gemma)0.033
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.007
Threshold uncertainty score0.037

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0070.033
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0070.009
Bibliometrics0.0060.005
Science and technology studies0.0010.001
Scholarly communication0.0020.002
Open science0.0020.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0050.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.342
Teacher spread0.316 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations43
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Hospital InfectionSame topicInfection Control and VentilationFrench-language works237,207