MétaCan
Menu
Back to cohort
Record W3081066246 · doi:10.1115/1.0000004v

Modelling of Echo Amplitude Fidelity for Transducer Bandwidth and Tfm Pixel Resolution

2021· preprint· en· W3081066246 on OpenAlexaboutno aff
David Lines, Ehsan Mohseni, Rastislav Zimermann, Carmelo Mineo, Charles MacLeod, Gareth Pierce, Anthony Gachagan

Bibliographic record

Venuenot available
Typepreprint
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsnot available
Fundersnot available
KeywordsAmplitudeTransducerEcho (communications protocol)Bandwidth (computing)AcousticsHigh fidelityPixelResolution (logic)FidelityComputer sciencePhysicsTelecommunicationsOpticsArtificial intelligence

Abstract

fetched live from OpenAlex

The unrectified (RF) A-scan contains additional information in the phase component compared to its envelope-detected equivalent, but requires higher temporal sampling rates for accurate representation and measurement. The same is true for the pixel density in images reconstructed by the Total Focusing Method (TFM). However the time to calculate each pixel means there is a drive to minimise the total number of pixels for faster real-time imaging rates. This conflicts with the ASME V requirement for the amplitude measurement error, usually a result of under-sampling, to be less than 2dB [1, 2]. There is therefore a need to model the process and to optimise the pixel density trade-off. Quadrature-sampling is a standard approach for optimised representation of band-limited signals [3-6] and is a suitable candidate for ultrasound A-scans. This greatly reduces the size of the Full Matrix Capture (FMC) data set and hence the data transfer rate and storage requirements. A parametric analysis model of the FMC and TFM processes has been created. This has been used to evaluate the amplitude fidelity on both A-scans and TFM images as the fractional bandwidth of the transducer increases and as the pixel density reduces. The results from quadrature-sampling are compared with those using conventional high temporal sampling rates. Results from the parametric analysis modelling are presented for targets at varying scan angles and depths into the material. These show that, for typical transducer fractional bandwidths (up to 75%), quadrature-sampling of the FMC A-scans gives the required amplitude fidelity with TFM image resolutions of around 4 pixels/wavelength. This is a similar result to those reported for conventional FMC acquisition and envelope detection TFM [7]. Extensions of the quadrature-sampling approach for higher fractional bandwidth are also presented. These results are currently being compared with those from real data acquired from Side-Drilled Hole (SDH) targets in a calibration block. An advantage of the FMC+TFM approach is the separation of the acquisition and reconstruction processes. This allows the latter to be redone at higher pixel resolutions for better human interpretation when an indication is observed in the lower pixel resolution images. High resolution TFM reconstructions have been performed on the quadrature-sampled data to confirm that this capability is still possible. A key outcome from this work is the range of optimised pixel resolution values that are safe to use for fast FMC+TFM imaging, as well as the supporting evidence needed to justify them. References [1] ASME Committee, ASME BPVC.V Article 4 Mandatory Appendix XI Full Matric Capture, ASME, 2019. [2] ASME Committee, ASME BPVC.V Article 4 Nonmandatory Appendix F - Examination of Welds Using Full Matric Capture., ASME, 2019. [3] C. E. Shannon, “Communication in the presence of noise,” Proceedings of the Institute of Radio Engineers, vol. 37, no. 1, p. 10–21, Jan 1949. [4] J. L. Brown Jnr., “On Quadrature Sampling of Bandpass Signals,” IEEE Transactions on Aerospace and Electronic Systems, Vols. AES-15, no. 3, pp. 366-371, May 1979. [5] J. L. Brown Jnr., “A simplified approach to optimum quadrature sampling,” The Journal of the Acoustical Society of America, vol. 67, no. 5, pp. 1659-1662, May 1980. [6] C. M. Rader, “A Simple Method for Sampling In-Phase and Quadrature Components,” IEEE Transactions on Aerospace and Electronic Systems, Vols. AES-20, no. 6, pp. 821-824, Nov 1984. [7] N. Badeau, G. Painchaud-April and A. Le Duff, “Use of the Total Focusing Method with the Envelope Feature,” Olympus NDT Canada, 30 March 2020. [Online]. Available: https://www.olympus-ims.com/en/resources/white-papers/use-of-the-total-focusing-method-with-the-envelope-feature/. [Accessed 30 March 2020].

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.045
GPT teacher head0.288
Teacher spread0.244 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2021
Admission routes1
Has abstractyes

Explore more

Same topicUltrasound Imaging and ElastographyFrench-language works237,207