Effect of Optimized Versus Guidelines‐Based Automated External Defibrillator Placement on Out‐of‐Hospital Cardiac Arrest Coverage: An In Silico Trial

2020· article· en· W3081228078 on OpenAlexaff
Christopher Sun, Lena Karlsson, Laurie J. Morrison, Steven C. Brooks, Fredrik Folke, Timothy C. Y. Chan

Bibliographic record

VenueJournal of the American Heart Association · 2020
Typearticle
Languageen
FieldMedicine
TopicCardiac Arrest and Resuscitation
Canadian institutionsQueen's UniversityUniversity of TorontoSt. Michael's Hospital
FundersDanish Foundation TrygFondenNovo Nordisk FondenTrygFonden
KeywordsMedicineAutomated external defibrillatorDefibrillationCardiopulmonary resuscitationLogistic regressionCohortEmergency medicineMedical emergencyInternal medicineResuscitation

Abstract

fetched live from OpenAlex

Background Mathematical optimization of automated external defibrillator (AED) placement may improve AED accessibility and out‐of‐hospital cardiac arrest (OHCA) outcomes compared with American Heart Association (AHA) and European Resuscitation Council (ERC) placement guidelines. We conducted an in silico trial (simulated prospective cohort study) comparing mathematically optimized placements with placements derived from current AHA and ERC guidelines, which recommend placement in locations where OHCAs are usually witnessed. Methods and Results We identified all public OHCAs of presumed cardiac cause from 2008 to 2016 in Copenhagen, Denmark. For the control, we computationally simulated placing 24/7‐accessible AEDs at every unique, public, witnessed OHCA location at monthly intervals over the study period. The intervention consisted of an equal number of simulated AEDs placements, deployed monthly, at mathematically optimized locations, using a model that analyzed historical OHCAs before that month. For each approach, we calculated the number of OHCAs in the study period that occurred within a 100‐m route distance based on Copenhagen’s road network of an available AED after it was placed (“OHCA coverage”). Estimated impact on bystander defibrillation and 30‐day survival was calculated by multivariate logistic regression. The control scenario involved 393 AEDs at historical, public, witnessed OHCA locations, covering 15.8% of the 653 public OHCAs from 2008 to 2016. The optimized locations provided significantly higher coverage (24.2%; P <0.001). Estimated bystander defibrillation and 30‐day survival rates increased from 15.6% to 18.2% ( P <0.05) and from 32.6% to 34.0% ( P <0.05), respectively. As a baseline, the 1573 real AEDs in Copenhagen covered 14.4% of the OHCAs. Conclusions Mathematical optimization can significantly improve OHCA coverage and estimated clinical outcomes compared with a guidelines‐based approach to AED placement.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.088
Threshold uncertainty score0.429

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.335
Teacher spread0.317 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of the American Heart AssociationSame topicCardiac Arrest and ResuscitationFrench-language works237,207