MétaCan
Menu
← Back to cohort
Record W3081833758 · doi:10.1371/journal.pone.0237492

Cost-effectiveness of a new autoantibody test added to Computed Tomography (CT) compared to CT surveillance alone in the diagnosis of lung cancer amongst patients with indeterminate pulmonary nodules

2020· article· en· W3081833758 on OpenAlexaff
Andrew Sutton, Gurdeep S. Sagoo, Leon Jackson, Geoffrey Hamilton-Fairley, Andrea Murray, Adam M. Hill

Bibliographic record

VenuePLoS ONE · 2020
Typearticle
Languageen
FieldMedicine
TopicLung Cancer Diagnosis and Treatment
Canadian institutionsInstitute of Health Economics
FundersSamsung Biomedical Research Institute
KeywordsMedicineLung cancerMalignancyQuality-adjusted life yearRadiologyCost effectivenessIndeterminateLung cancer screeningLungCost-effectiveness analysisComputed tomographyPre- and post-test probabilityInternal medicine

Abstract

fetched live from OpenAlex

Oncimmune's EarlyCDT®-Lung is a simple ELISA blood test that measures seven lung cancer specific autoantibodies and is used in the assessment of malignancy risk in patients with indeterminate pulmonary nodules (IPNs). The objective of this study was to examine the cost-effectiveness of EarlyCDT-Lung in the diagnosis of lung cancer amongst patients with IPNs in addition to CT surveillance, compared to CT surveillance alone which is the current recommendation by the British Thoracic Society guidelines. A model consisting of a combination of a decision tree and Markov model was developed using the outcome measure of the quality adjusted life year (QALY). A life-time time horizon was adopted. The model was parameterized using a range of secondary sources. At £70 per test, EarlyCDT-Lung and CT surveillance was found to be cost-effective compared to CT surveillance alone with an incremental cost-effectiveness ratio (ICER) of less than £2,500 depending on the test accuracy parameters used. It was also found that EarlyCDT-Lung can be priced up to £1,177 and still be cost-effective based on cost-effectiveness acceptance threshold of £20,000 / QALY. Further research to resolve parameter uncertainty, was not found to be of value. The results here demonstrate that at £70 per test the EarlyCDT-Lung will have a positive impact on patient outcomes and coupled with CT surveillance is a cost-effective approach to the management of patients with IPNs. The conclusions drawn from this analysis are robust to realistic variation in the parameters used in the model.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.015
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.012
Threshold uncertainty score0.027

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.015
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0020.004
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0020.002
Open science0.0010.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0050.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.288
Teacher spread0.249 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".