MétaCan
Menu
Back to cohort
Record W3086898696 · doi:10.1002/mp.14459

A novel minimally invasive dynamic‐shield, intensity‐modulated brachytherapy system for the treatment of cervical cancer

2020· article· en· W3086898696 on OpenAlexafffund
Marc Morcos, Majd Antaki, Akila N. Viswanathan, Shirin A. Enger

Bibliographic record

VenueMedical Physics · 2020
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsJewish General HospitalMcGill University Health CentreMcGill University
FundersNatural Sciences and Engineering Research Council of CanadaGovernment of Canada
KeywordsBrachytherapyNuclear medicineCervical cancerRadiation treatment planningMedicineDosimetryRadiation therapyRadiologyCancerInternal medicine

Abstract

fetched live from OpenAlex

Purpose To present a novel, MRI‐compatible dynamicshield intensity modulated brachytherapy (IMBT) applicator and delivery system using 192Ir, 75Se, and 169Yb radioisotopes for the treatment of locally advanced cervical cancer. Needle‐free IMBT is a promising technique for improving target coverage and organs at risk (OAR) sparing. Methods and materials The IMBT delivery system dynamically controls the rotation of a novel tungsten shield placed inside an MRI‐compatible, 6‐mm wide intrauterine tandem. Using 36 cervical cancer cases, conventional intracavitary brachytherapy (IC‐BT) and intracavitary/interstitial brachytherapy (IC/IS‐BT) (10Ci 192Ir) plans were compared to IMBT (10Ci 192Ir; 11.5Ci 75Se; 44Ci 169Yb). All plans were generated using the Geant4‐based Monte Carlo dose calculation engine, RapidBrachyMC. Treatment plans were optimized then normalized to the same high‐risk clinical target volume (HR‐CTV) D90 and the D2cc for bladder, rectum, and sigmoid in the research brachytherapy planning system, RapidBrachyMCTPS. Plans were renormalized until either of the three OAR reached dose limits to calculate the maximum achievable HR‐CTV D90 and D98. Results Compared to IC‐BT, IMBT with either of the three radionuclides significantly improves the HR‐CTV D90 and D98 by up to 5.2% ± 0.3% (P < 0.001) and 6.7% ± 0.5% (P < 0.001), respectively, with the largest dosimetric enhancement when using 169Yb followed by 75Se and then 192Ir. Similarly, D2cc for all OAR improved with IMBT by up to 7.7% ± 0.6% (P < 0.001). For IC/IS‐BT cases, needle‐free IMBT achieved clinically acceptable plans with 169Yb‐based IMBT further improving HR‐CTV D98 by 1.5% ± 0.2% (P = 0.034) and decreasing sigmoid D2cc by 1.9% ± 0.4% (P = 0.048). Delivery times for IMBT are increased by a factor of 1.7, 3.3, and 2.3 for 192Ir, 75Se, and 169Yb, respectively, relative to conventional 192Ir BT. Conclusions Dynamic shield IMBT provides a promising alternative to conventional IC‐ and IC/IS‐BT techniques with significant dosimetric enhancements and even greater improvements with intermediate energy radionuclides. The ability to deliver a highly conformal, OAR‐sparing dose without IS needles provides a simplified method for improving the therapeutic ratio less invasively and in a less resource intensive manner.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.289
Teacher spread0.271 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207