MétaCan
Menu
Back to cohort
Record W3087565379

Evaluating on-eye wavefront aberrations of a soft contact lens with an optical design simulating orthokeratology

2020· article· en· W3087565379 on OpenAlexaff
Xu Cheng, Mona Almaghshi, Mike Yang, Alyra J. Shaw, Noel A. Brennan

Bibliographic record

VenueQUT ePrints (Queensland University of Technology) · 2020
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdaptive optics and wavefront sensing
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsOrthokeratologyWavefrontContact lensOpticsLens (geology)OptometryPhysicsMedicineCornea
DOInot available

Abstract

fetched live from OpenAlex

Purpose : Orthokeratology (OK) has been shown to be effective in slowing myopia progression. The mechanism of action is hypothesized to be the resultant optical impact to the eye. However, a soft contact lens (SCL) designed to simulate the optical effect of OK (simOK) for myopia control was found to be ineffective in a randomized controlled myopia control trial. The purpose of this study was to evaluate on-eye wavefront aberrations of the simOK lens by comparing to that of successful OK patients.<br/><br/>Methods : Distance (4 m) and near (25 cm) wavefront aberrations were measured with an open-field Shack-Hartmann aberrometer in 8 OK-treated patients (bare eye only) and 20 non-OK subjects with bare eye (simOK-BE) and with simOK lens on-eye (simOK-LOE) between the age of 7 and 25 years. Zernike expansions of wavefront aberration functions to the 6th order were used to determine aberration coefficients for a series of pupil diameters. Zernike coefficient of primary spherical aberration (Z40), Root-Mean-Square (RMS) of 3rd order and total Higher Order Aberrations (HOA, 3rd – 6th orders) at a 5 mm aperture were compared between simOK-BE and SimOK-LOE and between OK and simOK-LOE. A general linear mixed model with a type I error of 0.05 was used for statistical analysis.<br/><br/>Results : Under a 5mm pupil and with a 4-m target, the means (SD) of Z40 were 0.054 (0.050), 0.350 (0.066), and 0.364 (0.212) microns in simOK-BE, simOK-LOE and OK, respectively. Compared to simOK-BE, Z40 was significantly increased with simOK-LOE with least-square-mean (LSM) difference of 0.297 micron (95% CI: 0.255, 0.338, p<0.001). There was no significant difference in Z40 between simOK-LOE and OK (LSM difference (95%CI): -0.034 micron (-0.148, 0.080), p=0.783). Similar results were found between conditions for near wavefront and for total 3rd order aberrations and total HOAs.<br/><br/>Conclusions : This exploratory study demonstrated that wearing SCL designed to simulate the optical impact of OK resulted in a significant increase of HOAs in the eye. The magnitude of HOAs, including primary spherical aberration and 3rd order aberrations, was similar to those of the OK patients. To fully characterize the on-eye optical performance of the simOK lens and understand the mechanism of action of OK, additional analysis of off-axis refraction and accommodative response with the simOK lens will be examined.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.745
Threshold uncertainty score0.650

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.046
GPT teacher head0.272
Teacher spread0.226 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueQUT ePrints (Queensland University of Technology)Same topicAdaptive optics and wavefront sensingFrench-language works237,207