MétaCan
Menu
Back to cohort
Record W3088875917 · doi:10.1038/s41598-020-72334-7

Site-selective mapping of metastable states using electron-beam induced luminescence microscopy

2020· article· en· W3088875917 on OpenAlexfundno aff
Raju Kumar, Lisa I. D. J. Martin, Dirk Poelman, Dimitri Vandenberghe, Johan De Grave, M. Kook, Mayank Jain

Bibliographic record

VenueScientific Reports · 2020
Typearticle
Languageen
FieldPhysics and Astronomy
TopicForce Microscopy Techniques and Applications
Canadian institutionsnot available
FundersUniversiteit GentSimon Fraser University
KeywordsMetastabilityLuminescenceMicroscopyElectron microscopeMaterials scienceCathode rayAtomic physicsElectronOptoelectronicsNanotechnologyChemistryOpticsPhysicsNuclear physics

Abstract

fetched live from OpenAlex

Abstract Metastable states created by electron or hole capture in crystal defects are widely used in dosimetry and photonic applications. Feldspar, the most abundant mineral in the Earth’s crust (> 50%), generates metastable states with lifetimes of millions of years upon exposure to ionizing radiation. Although feldspar is widely used in dosimetry and geochronometry, the creation of metastable states and charge transfer across them is poorly understood. Understanding such phenomena requires next-generation methods based on high-resolution, site-selective probing of the metastable states. Recent studies using site-selective techniques such as photoluminescence (PL), and radioluminescence (RL) at 7 K have revealed that feldspar exhibits two near-infrared (NIR) emission bands peaking at 880 nm and 955 nm, which are believed to arise from the principal electron-trapping states. Here, we map for the first time the electron-trapping states in potassium-rich feldspar using spectrally-resolved cathodoluminescence microscopy at a spatial resolution of ~ 6 to 22 µm. Each pixel probed by a scanning electron microscope provides us a cathodoluminescence spectrum (SEM-CL) in the range 600–1000 nm, and elemental data from energy-dispersive x-ray (EDX) spectroscopy. We conclude that the two NIR emissions are spatially variable and, therefore, originate from different sites. This conclusion contradicts the existing model that the two emissions arise from two different excited states of a principal trap. Moreover, we are able to link the individual NIR emission peaks with the geochemical variations (K, Na and Fe concentration), and propose a model that explains the quenching of the NIR emission by Fe 4+ . Our study contributes to an improved understanding of charge storage in feldspathic minerals, with implications for developing sub-single grain (micrometer scale) measurement techniques in radiation dosimetry.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.022
Threshold uncertainty score0.579

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.289
Teacher spread0.268 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueScientific ReportsSame topicForce Microscopy Techniques and ApplicationsFrench-language works237,207