MétaCan
Menu
Back to cohort
Record W3093629310 · doi:10.2106/jbjs.20.00351

Influence of Femoral Component Design on Proximal Femoral Bone Mass After Total Hip Replacement

2020· article· en· W3093629310 on OpenAlexaff
Pablo A. Slullitel, Mohit M. Mahatma, Mohsen Farzi, George Grammatopoulos, J. Mark Wilkinson, Paul E. Beaulé

Bibliographic record

VenueJournal of Bone and Joint Surgery · 2020
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsOttawa Hospital
Fundersnot available
KeywordsMedicineCalcarPeriprostheticProsthesisBone remodelingFemoral neckBone densityTrochanterDentistryFemurBone mineralSurgeryArthroplastyInternal medicineOsteoporosis

Abstract

fetched live from OpenAlex

BACKGROUND: In this randomized controlled trial (RCT), we compared bone remodeling and bone turnover between 2 total hip arthroplasty implants-the short, proximally porous-coated Tri-Lock Bone-Preservation Stem and a conventional, fully-coated Corail prosthesis-over a 2-year postoperative period. METHODS: Forty-six participants received the Tri-Lock prosthesis and 40 received the Corail prosthesis. At baseline, the 2 groups had similar demographics, proximal femoral bone mineral density (BMD), bone turnover markers, radiographic canal flare index, and patient-reported outcome measure (PROM) scores. Outcomes were measured at weeks 26, 52, and 104. RESULTS: Loss of periprosthetic bone, measured by high-sensitivity dual x-ray absorptiometry region-free analysis (DXA-RFA), was identified at the calcar and proximal-lateral aspect of the femur in both prosthesis groups (p < 0.05). However, the conventional prosthesis was associated with a smaller reduction in BMD compared with the bone-preservation prosthesis (p < 0.001). This effect was most prominent in the region of the femoral calcar and greater trochanter. A small gain in BMD was also identified in some areas, and this gain was greater with the conventional than the bone-preservation prosthesis (p < 0.001). The 2 groups had similar changes in bone turnover markers and improvement in PROM scores over the study period (p > 0.05). The adverse-event rate was also similar between the groups (p > 0.05). CONCLUSIONS: This RCT shows that prostheses intended to preserve proximal femoral bone do not necessarily perform better in this regard than conventional cementless designs. DXA-RFA is a sensitive tool for detecting spatially complex patterns of periprosthetic bone remodeling. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.017

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.005
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0030.002
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.243
Teacher spread0.204 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Bone and Joint SurgerySame topicOrthopaedic implants and arthroplastyFrench-language works237,207