MétaCan
Menu
Back to cohort

Frequency Response Analysis of Actively Cooled Nylon Twisted Coiled Actuators for Use in Wrist Rehabilitation Devices

2020· article· en· W3094172120 on OpenAlexaff
Brandon P.R. Edmonds, Ana Luisa Trejos

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicAdvanced Sensor and Energy Harvesting Materials
Canadian institutionsWestern University
Fundersnot available
KeywordsWristWearable computerActuatorFrequency responseComputer scienceMechatronicsSimulationEngineeringElectrical engineeringMedicineSurgeryEmbedded system

Abstract

fetched live from OpenAlex

Recovery from an upper limb musculoskeletal injury can take months or years, and often requires continuous visits to a therapist for specialized training and evaluation. Research has found that active assistance using mechatronic devices can significantly improve the quality and speed of recovery, especially when used for periods beyond a typical clinical appointment. However, current devices commonly use conventional actuation methods that are too heavy and rigid to be worn as a portable system outside of clinical settings. A recently discovered actuator made from twisting and coiling nylon thread (TCA) has the potential to improve wearable mechatronic designs due to its high power density, large strain, and inherent compliance. TCAs require heat to contract, which limits the actuation bandwidth due to the slow cooling rate, making it difficult to implement in wearable devices that must respond to voluntary motion. This study presents an active cooling method for TCAs to improve their frequency response and evaluates their feasibility in a wrist orthosis design based on real anatomical constraints. The frequency response was evaluated using a square wave input of varying frequency to provide actuation cycles of resistive heating and forced convective cooling, while measuring displacement at constant load. The results show that the TCA was able to respond to frequencies of up to 6.5 Hz, and also achieve full wrist range of motion at 0.55 Hz for loads equivalent to the weight of an average adult hand. This indicates that the proposed wrist orthosis could effectively assist the wrist throughout its entire range of motion and at the speeds required for voluntary motion using parallel TCAs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.259
Teacher spread0.231 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2020
Admission routes1
Has abstractyes

Explore more

Same topicAdvanced Sensor and Energy Harvesting MaterialsFrench-language works237,207