MétaCan
Menu
Back to cohort
Record W3094234523 · doi:10.1016/j.xkme.2020.07.007

Hemodialysis With the Quanta SC+: Efficacy and Safety of a Self-care Hemodialysis Machine

2020· article· en· W3094234523 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueKidney Medicine · 2020
Typearticle
Languageen
FieldMedicine
TopicDialysis and Renal Disease Management
Canadian institutionsOrthopaedic Innovation CentreUniversity of Manitoba
Fundersnot available
KeywordsHemodialysisMedicineMedical prescriptionDialysisAdverse effectHome hemodialysisInternal medicineKidney diseaseIntensive care medicineEmergency medicinePharmacology

Abstract

fetched live from OpenAlex

Rationale & ObjectiveMost patients with kidney failure receive hemodialysis 3 times per week in a facility. More frequent and longer duration dialysis prescriptions improve a number of key outcome measures. These prescriptions are best suited to self-care and home regimens. The Quanta SC+ hemodialysis system is a novel device with demonstrated ease of use for patients and health care practitioners through human factors testing. The primary objective of this study is to report the efficacy and safety of the SC+ system using conventional hemodialysis prescriptions.Study DesignNonrandomized observational study.Setting & ParticipantsPrevalent hemodialysis patients in 4 sites in the United Kingdom were recruited to switch from their current device to the SC+ system with no other changes to their prescription.InterventionsSC+ hemodialysis system.OutcomesEfficacy data were collected in terms of dialysis adequacy, urea reduction ratios, and net fluid removal accuracy.Results60 patients were enrolled in the study, resulting in 1,333 evaluable treatments. The threshold single-pool Kt/V of 1.2 was exceeded in 96.6% of treatments in patients receiving 3-times-weekly regimens, whereas the threshold standard Kt/V of 2.1 was exceeded in 94% of treatments and 97.6% of treatments in patients without significant residual kidney function. Ultrafiltration accuracy was determined by measuring net fluid removal and validated to be within acceptable limits. The adverse event profile during treatment was typical of hemodialysis. There were no serious adverse events.LimitationsFew patients on high-frequency treatment regimens were enrolled.ConclusionsThe SC+ system delivers safe and effective hemodialysis across a range of patients and dialysis prescriptions. It is one of the smallest systems available and has validated usability for patients to perform self-care safely with minimal training. This device may encourage patients to feel empowered to take on home hemodialysis, unlocking beneficial clinical and patient-reported outcomes associated with these modalities. Most patients with kidney failure receive hemodialysis 3 times per week in a facility. More frequent and longer duration dialysis prescriptions improve a number of key outcome measures. These prescriptions are best suited to self-care and home regimens. The Quanta SC+ hemodialysis system is a novel device with demonstrated ease of use for patients and health care practitioners through human factors testing. The primary objective of this study is to report the efficacy and safety of the SC+ system using conventional hemodialysis prescriptions. Nonrandomized observational study. Prevalent hemodialysis patients in 4 sites in the United Kingdom were recruited to switch from their current device to the SC+ system with no other changes to their prescription. SC+ hemodialysis system. Efficacy data were collected in terms of dialysis adequacy, urea reduction ratios, and net fluid removal accuracy. 60 patients were enrolled in the study, resulting in 1,333 evaluable treatments. The threshold single-pool Kt/V of 1.2 was exceeded in 96.6% of treatments in patients receiving 3-times-weekly regimens, whereas the threshold standard Kt/V of 2.1 was exceeded in 94% of treatments and 97.6% of treatments in patients without significant residual kidney function. Ultrafiltration accuracy was determined by measuring net fluid removal and validated to be within acceptable limits. The adverse event profile during treatment was typical of hemodialysis. There were no serious adverse events. Few patients on high-frequency treatment regimens were enrolled. The SC+ system delivers safe and effective hemodialysis across a range of patients and dialysis prescriptions. It is one of the smallest systems available and has validated usability for patients to perform self-care safely with minimal training. This device may encourage patients to feel empowered to take on home hemodialysis, unlocking beneficial clinical and patient-reported outcomes associated with these modalities.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.538
Threshold uncertainty score0.562

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.248
Teacher spread0.235 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it