MétaCan
Menu
Back to cohort
Record W3094275932 · doi:10.1115/fpmc2020-2747

Fluid Property Effects on Power Consumption in a Hydraulic System at Low Temperatures

2020· article· en· W3094275932 on OpenAlexaff
Cecilia Dai, Kimberly Rodriguez

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicHydraulic and Pneumatic Systems
Canadian institutionsPetro-Canada
Fundersnot available
KeywordsHydraulic machineryMechanicsFluid powerHydraulic fluidTurbulenceLaminar flowTorqueEnvironmental scienceHydraulic pumpPressure dropControl theory (sociology)Materials scienceEngineeringMechanical engineeringThermodynamicsComputer sciencePhysics

Abstract

fetched live from OpenAlex

Abstract Hydraulic systems that are operated outdoors during winter can be exposed to extreme low temperatures. Low temperature thickening of the hydraulic fluid can increase power consumption, cause pump cavitation, and stall system actuation. In this study, the response time and power consumption of a hydraulic vehicle restraint system that is used outdoors year-round was evaluated at low temperatures. This safety device incorporated proximity switches that triggered a machine “fault” when the time delay between the locked and unlocked positions exceeded 8 seconds. Straight- and multi-grade ISO VG 32 and 46 fluids were compared in the device. The multi-grade oils were able to function at a lower temperature without faulting. The effect of system operating conditions and fluid properties on pump input power was evaluated. The input power was determined from measurements of pump rotational frequency and torque. Pump torque increased as the oil temperature decreased. As a result, low-temperature operating conditions resulted in a higher system power requirements. An empirical model was developed to investigate the effects of turbulent and laminar flow conditions on the hydraulic system power requirements. A comparison of model standard errors revealed that viscosity-dependent laminar losses had a greater impact on system performance than density-dependent turbulent losses. Since the viscosity coefficients of the fluids were very high at the test temperature, it was theorized that pressure drop in the hydraulic lines was affecting system response. Hydraulic system simulations were conducted via Automation Studio. Cylinder retraction velocities were evaluated with larger ID cap- and rod-side hoses. Increasing the cap-side hose diameter enhanced the low temperature performance of the system. Changes to the rod-side hose had minimal effect. These results provide new insights for system design and the formulation of hydraulic fluids used in extreme low temperature operations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.676
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.194
Teacher spread0.184 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2020
Admission routes1
Has abstractyes

Explore more

Same topicHydraulic and Pneumatic SystemsFrench-language works237,207