MétaCan
Menu
Back to cohort
Record W3094350134 · doi:10.1016/s2589-7500(20)30221-1

Chest x-ray analysis with deep learning-based software as a triage test for pulmonary tuberculosis: a prospective study of diagnostic accuracy for culture-confirmed disease

2020· article· en· W3094350134 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.
aboutThe title or abstract carries a Canadian signal from the geographic lexicon.

Bibliographic record

VenueThe Lancet Digital Health · 2020
Typearticle
Languageen
FieldMedicine
TopicTuberculosis Research and Epidemiology
Canadian institutionsUniversity of British ColumbiaMcGill UniversityMcGill University Health Centre
FundersCanadian Institutes of Health Research
KeywordsMedicineTriageTuberculosisLogistic regressionPulmonary tuberculosisRadiological weaponInternal medicineReceiver operating characteristicProspective cohort studyDiseaseRadiologyEmergency medicinePathology

Abstract

fetched live from OpenAlex

BACKGROUND: Deep learning-based radiological image analysis could facilitate use of chest x-rays as triage tests for pulmonary tuberculosis in resource-limited settings. We sought to determine whether commercially available chest x-ray analysis software meet WHO recommendations for minimal sensitivity and specificity as pulmonary tuberculosis triage tests. METHODS: We recruited symptomatic adults at the Indus Hospital, Karachi, Pakistan. We compared two software, qXR version 2.0 (qXRv2) and CAD4TB version 6.0 (CAD4TBv6), with a reference of mycobacterial culture of two sputa. We assessed qXRv2 using its manufacturer prespecified threshold score for chest x-ray classification as tuberculosis present versus not present. For CAD4TBv6, we used a data-derived threshold, because it does not have a prespecified one. We tested for non-inferiority to preset WHO recommendations (0·90 for sensitivity, 0·70 for specificity) using a non-inferiority limit of 0·05. We identified factors associated with accuracy by stratification and logistic regression. FINDINGS: We included 2198 (92·7%) of 2370 enrolled participants. 2187 (99·5%) of 2198 were HIV-negative, and 272 (12·4%) had culture-confirmed pulmonary tuberculosis. For both software, accuracy was non-inferior to WHO-recommended minimum values (qXRv2 sensitivity 0·93 [95% CI 0·89-0·95], non-inferiority p=0·0002; CAD4TBv6 sensitivity 0·93 [0·90-0·96], p<0·0001; qXRv2 specificity 0·75 [0·73-0·77], p<0·0001; CAD4TBv6 specificity 0·69 [0·67-0·71], p=0·0003). Sensitivity was lower in smear-negative pulmonary tuberculosis for both software, and in women for CAD4TBv6. Specificity was lower in men and in those with previous tuberculosis, and reduced with increasing age and decreasing body mass index. Smoking and diabetes did not affect accuracy. INTERPRETATION: In an HIV-negative population, these software met WHO-recommended minimal accuracy for pulmonary tuberculosis triage tests. Sensitivity will be lower when smear-negative pulmonary tuberculosis is more prevalent. FUNDING: Canadian Institutes of Health Research.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.045
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.088
Threshold uncertainty score0.963

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.045
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.041
GPT teacher head0.357
Teacher spread0.315 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it