MétaCan
Menu
Back to cohort
Record W3094534649 · doi:10.1111/srt.12956

Intra‐ and inter‐evaluator reliability of the MyotonPRO for the assessment of the viscoelastic properties of caesarean section scar and unscarred skin

2020· article· en· W3094534649 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueSkin Research and Technology · 2020
Typearticle
Languageen
FieldHealth Professions
TopicPressure Ulcer Prevention and Management
Canadian institutionsUniversité de Sherbrooke
Fundersnot available
KeywordsViscoelasticityScarsCaesarean sectionStiffnessMedicineMaterials scienceSurgeryComposite material

Abstract

fetched live from OpenAlex

BACKGROUND: The clinical evaluation of viscoelastic properties of the Caesarean section (C-section) scar, such as stiffness and elasticity, is usually carried out using subjective scales and palpation techniques. There is currently no reliable and valid tool that objectively quantifies these properties. The MyotonPRO could fill this gap. MATERIALS AND METHODS: Nineteen healthy women aged between 21 and 40 years with C-section scars participated in this reliability study. Two points, one on the scar and one on unscarred skin, were measured four times successively with the MyotonPRO by three independent evaluators on the same day. The intra-class correlation (ICC) coefficients were estimated using a two-factor ANOVA to determine the inter- and intra-rater reliability. The capacity of the MyotonPRO to discriminate the viscoelastic properties of the C-Section scar against unscarred skin was assessed using the Wilcoxon signed rank test. RESULTS: The intra- and inter-rater reliability of the viscoelastic property measurements was good to excellent (ICC 0.99-1.00 and 0.87-0.98, respectively). There was no significant difference between C-section scar and unscarred skin in terms of elasticity (P = .737). Significant differences between C-section scars and unscarred skin tissue were observed for tone (P < .001), stiffness (P < .001), creep (P < .001), and mechanical stress relaxation time (P < .001). CONCLUSION: The MyotonPRO is a reliable tool for an objective measurement of the viscoelastic properties of the C-section scar and unscarred skin. The MyotonPRO can discriminate the viscoelastic properties of the C-section scar against the unscarred skin, for tone, stiffness, creep and relaxation times, but not for elasticity.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.148
Threshold uncertainty score0.389

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.089
GPT teacher head0.438
Teacher spread0.350 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it