Evaluation of fully automated myocardial segmentation techniques in native and contrast‐enhanced T1‐mapping cardiovascular magnetic resonance images using fully convolutional neural networks
Bibliographic record
Abstract
PURPOSE: T1-mapping cardiac magnetic resonance (CMR) imaging permits noninvasive quantification of myocardial fibrosis (MF); however, manual delineation of myocardial boundaries is time-consuming and introduces user-dependent variability for such measurements. In this study, we compare several automated pipelines for myocardial segmentation of the left ventricle (LV) in native and contrast-enhanced T1-maps using fully convolutional neural networks (CNNs). METHODS: Sixty patients with known MF across three distinct cardiomyopathy states (20 ischemic (ICM), 20 dilated (DCM), and 20 hypertrophic (HCM)) underwent a standard CMR imaging protocol inclusive of cinematic (CINE), late gadolinium enhancement (LGE), and pre/post-contrast T1 imaging. Native and contrast-enhanced T1-mapping was performed using a shortened modified Look-Locker imaging (shMOLLI) technique at the basal, mid-level, and/or apex of the LV. Myocardial segmentations in native and post-contrast T1-maps were performed using three state-of-the-art CNN-based methods: standard U-Net, densely connected neural networks (Dense Nets), and attention networks (Attention Nets) after dividing the dataset using fivefold cross validation. These direct segmentation techniques were compared to an alternative registration-based segmentation method, wherein spatially corresponding CINE images are segmented automatically using U-Net, and a nonrigid registration technique transforms and propagates CINE contours to the myocardial regions of T1-maps. The methodologies were validated in 125 native and 100 contrast-enhanced T1-maps using standard segmentation accuracy metrics. Pearson correlation coefficient r and Bland-Altman analysis were used to compare the computed global T1 values derived by manual, U-Net, and CINE registration methodologies. RESULTS: The U-Net-based method yielded optimal results in myocardial segmentation of native, contrast-enhanced, and CINE images compared to Dense Nets and Attention Nets. The direct U-Net-based method outperformed the CINE registration-based method in native T1-maps, yielding Dice similarity coefficient (DSC) of 82.7 ± 12% compared to 81.4 ± 6.9% (P < 0.0001). However, in contrast-enhanced T1-maps, the CINE-registration-based method outperformed direct U-Net segmentation, yielding DSC of 77.0 ± 9.6% vs 74.2 ± 18% across all patient groups (P = 0.0014) and specifically 73.2 ± 7.3% vs 65.5 ± 18% in the ICM patient group. High linear correlation of global T1 values was demonstrated in Pearson analysis of the U-Net-based technique and the CINE-registration technique in both native T1-maps (r = 0.93, P < 0.0001 and r = 0.87, P < 0.0001, respectively) and contrast-enhanced T1-maps (r = 0.93, P < 0.0001 and r = 0.98, P < 0.0001, respectively). CONCLUSIONS: The direct U-Net-based myocardial segmentation technique provided accurate, fully automated segmentations in native and contrast-enhanced T1-maps. Myocardial borders can alternatively be segmented from spatially matched CINE images and applied to T1-maps via deformation and propagation through a modality-independent neighborhood descriptor (MIND). The direct U-Net approach is more efficient in myocardial segmentation of native T1-maps and eliminates cross-technique dependence. However, the CINE-registration-based technique may be more appropriate for contrast-enhanced T1-maps and/or for patients with dense regions of replacement fibrosis, such as those with ICM.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.002 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".