MétaCan
Menu
Back to cohort
Record W3100166103 · doi:10.1044/2020_jslhr-20-00212

Evaluation of Acoustic Analyses of Voice in Nonoptimized Conditions

2020· article· en· W3100166103 on OpenAlexaff
Benjamin van der Woerd, Min Wu, Vijay Parsa, Philip C. Doyle, Kevin Fung

Bibliographic record

VenueJournal of Speech Language and Hearing Research · 2020
Typearticle
Languageen
FieldMedicine
TopicVoice and Speech Disorders
Canadian institutionsWestern University
Fundersnot available
KeywordsAudiologyPsychologyPhonationMedicine

Abstract

fetched live from OpenAlex

Objectives This study aimed to evaluate the fidelity and accuracy of a smartphone microphone and recording environment on acoustic measurements of voice. Method A prospective cohort proof-of-concept study. Two sets of prerecorded samples (a) sustained vowels (/a/) and (b) Rainbow Passage sentence were played for recording via the internal iPhone microphone and the Blue Yeti USB microphone in two recording environments: a sound-treated booth and quiet office setting. Recordings were presented using a calibrated mannequin speaker with a fixed signal intensity (69 dBA), at a fixed distance (15 in.). Each set of recordings (iPhone—audio booth, Blue Yeti—audio booth, iPhone—office, and Blue Yeti—office), was time-windowed to ensure the same signal was evaluated for each condition. Acoustic measures of voice including fundamental frequency ( f o ), jitter, shimmer, harmonic-to-noise ratio (HNR), and cepstral peak prominence (CPP), were generated using a widely used analysis program (Praat Version 6.0.50). The data gathered were compared using a repeated measures analysis of variance. Two separate data sets were used. The set of vowel samples included both pathologic ( n = 10) and normal ( n = 10), male ( n = 5) and female ( n = 15) speakers. The set of sentence stimuli ranged in perceived voice quality from normal to severely disordered with an equal number of male ( n = 12) and female ( n = 12) speakers evaluated. Results The vowel analyses indicated that the jitter, shimmer, HNR, and CPP were significantly different based on microphone choice and shimmer, HNR, and CPP were significantly different based on the recording environment. Analysis of sentences revealed a statistically significant impact of recording environment and microphone type on HNR and CPP. While statistically significant, the differences across the experimental conditions for a subset of the acoustic measures (viz., jitter and CPP) have shown differences that fell within their respective normative ranges. Conclusions Both microphone and recording setting resulted in significant differences across several acoustic measurements. However, a subset of the acoustic measures that were statistically significant across the recording conditions showed small overall differences that are unlikely to have clinical significance in interpretation. For these acoustic measures, the present data suggest that, although a sound-treated setting is ideal for voice sample collection, a smartphone microphone can capture acceptable recordings for acoustic signal analysis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.006
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.291
GPT teacher head0.517
Teacher spread0.226 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations39
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Speech Language and Hearing ResearchSame topicVoice and Speech DisordersFrench-language works237,207