Primer and Historical Review on Rapid Cardiac <scp>CINE MRI</scp>

2020· review· en· W3100575237 on OpenAlexafffund
Aaron D. Curtis, Hai‐Ling Margaret Cheng

Bibliographic record

VenueJournal of Magnetic Resonance Imaging · 2020
Typereview
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsTed Rogers Centre for Heart ResearchUniversity of Toronto
FundersNatural Sciences and Engineering Research Council of CanadaCanada Foundation for Innovation
KeywordsComputer scienceAccelerationCompressed sensingArtificial intelligenceRegularization (linguistics)Context (archaeology)Iterative reconstructionReal-time MRICardiac imagingComputer visionMagnetic resonance imagingMedicinePhysicsRadiology

Abstract

fetched live from OpenAlex

Acceleration is an important consideration when imaging moving organs such as the heart. Not only does acceleration enable motion-free scans but, more importantly, it lies at the heart of capturing the dynamics of cardiac motion. For over three decades, various ingenious approaches have been devised and implemented for rapid CINE MRI suitable for dynamic cardiac imaging. Virtually all techniques relied on acquiring less data to reduce acquisition times. Parallel imaging was among the first of these innovations, using multiple receiver coils and mathematical algorithms for reconstruction; acceleration factors of 2 to 3 were readily achieved in clinical practice. However, in the context of imaging dynamic events, further decreases in scan time beyond those provided by parallel imaging were possible by exploiting temporal coherencies. This recognition ushered in the era of k-t accelerated MRI, which utilized predominantly statistical methods for image reconstruction from highly undersampled k-space. Despite the successes of k-t acceleration methods, however, the accuracy of reconstruction was not always guaranteed. To address this gap, MR physicists and mathematicians applied compressed sensing theory to ensure reconstruction accuracy. Reconstruction was, indeed, more robust, but it required optimizing regularization parameters and long reconstruction times. To solve the limitations of all previous methods, researchers have turned to artificial intelligence and deep neural networks for the better part of the past decade, with recent results showing rapid, robust reconstruction. This review provides a comprehensive overview of key developments in the history of CINE MRI acceleration, and offers a unique and intuitive explanation behind the techniques and underlying mathematics.Level of Evidence: 5Technical Efficacy Stage: 1.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.876
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0030.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.337
Teacher spread0.304 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations38
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Magnetic Resonance ImagingSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207