MétaCan
Menu
← Back to cohort
Record W3102890802 · doi:10.1111/cid.12961

Characteristics and frequency distribution of bone defect configurations in peri‐implantitis lesions—A series of 193 cases

2020· article· en· W3102890802 on OpenAlexvenueno aff
Christian Wehner, Kristina Bertl, Gerlinde Durstberger, Christoph Arnhart, Xiaohui Rausch‐Fan, Andreas Stavropoulos

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2020
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
FundersMedizinische Universität WienUniversität Wien
KeywordsDehiscenceDentistryImplantAlveolar ridgeMedicinePeri-implantitisDental alveolusEdentulismAlveolar processOrthodonticsSurgeryOral health

Abstract

fetched live from OpenAlex

BACKGROUND: Knowledge on peri-implantitis bone defect characteristics and predictors is still limited. PURPOSE: To describe peri-implantitis bone defect characteristics and identify possible predictors. METHODS: Various parameters at patient- (age, gender, smoking, and supra-structure), implant- (surface, type, connection, platform, and misfit), and site level (region, alveolar ridge position, defect characteristics, neighboring structure) were recorded retrospectively. RESULTS: Among 193 implants, the most prevalent defects were class Ic (25.4%), and Id (23.8%); a previously non-described category "class Id with only one bone wall" was frequently observed (11.9%). Mean intrabony defect depth and width ranged from 4.5 to 6.2 mm and from 2.7 to 2.9 mm, respectively; mean dehiscence extent ranged from 2.8 to 7.0 mm. A total of 37.8% of the defects presented horizontal bone loss and an intrabony component; in 52.7% of the implants, total defect extent was >6 mm. Jaw region, implant position within the alveolar ridge, and implant/abutment misfit showed significant associations either to defect configuration and/or defect extent. CONCLUSION: (a) Most common peri-implantitis defects exhibited a combination of intrabony component and a buccal/oral dehiscence, while purely circumferential defects were relatively seldom; (b) implants with defects with bone dehiscence were placed more frequently closer to the lateral aspect of the ridge harboring the dehiscence; (c) implants placed in the lower anterior region had the highest risk for more severe peri-implant bone loss; and (d) peri-implant bone defects with only a single bone wall appropriate for regenerative procedure were relatively frequent.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.145
GPT teacher head0.435
Teacher spread0.290 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→