MétaCan
Menu
Back to cohort
Record W3105979951 · doi:10.21037/jtd-20-1492

Minimally invasive ventricular assist device implantation

2021· review· en· W3105979951 on OpenAlexaff
Florian Fahr, Asim Khan, Christian Bireta, M. Nozdrzykowski, Stefan Feder, Nikhil Deshmukh, Manal Jubeh, Sandra Eifert, Khalil Jawad, Uwe Schulz, Michael A. Borger, Diyar Saeed

Bibliographic record

VenueJournal of Thoracic Disease · 2021
Typereview
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsMedicineEconomic shortageMedian sternotomySurgeryPericardiumInvasive surgeryVentricular assist deviceImplantIntensive care medicineHeart failureCardiology

Abstract

fetched live from OpenAlex

Durable mechanical circulatory support (MCS) systems are established therapy option in patients with end-stage heart failure, with increasing importance during the last years due to donor organ shortage. Left ventricular assist devices (LVADs) are traditionally implanted through median sternotomy (MS). However, improvement in the pump designs during the last years led to evolvement of new surgical approaches that aim to reduce the invasiveness of the procedure. Numerous reports and studies have shown the viability and possible advantages of less-invasive approach compared to the sternotomy approach. The less invasive implant strategies for LVADs, while vague in definition, are characterized by minimizing surgical trauma and if possible, cardio-pulmonary bypass related complications. Usually it involves minimizing or completely avoiding sternal trauma, avoiding heart luxation while simultaneously leaving the major part of pericardium intact. There is no consensus between the centers regarding the ideal approach for LVAD implantation. Some centers, like our center, perform by default VAD implantation using less invasive approach in almost all patients and some centers use only sternotomy approach. The aim of this review article is to shed light on the currently available less invasive options of LVAD implantation, with particular focus on the centrifugal pumps, and their possible advantages compared to traditional sternotomy approach.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.004
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.041
GPT teacher head0.344
Teacher spread0.303 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Thoracic DiseaseSame topicMechanical Circulatory Support DevicesFrench-language works237,207