MétaCan
Menu
Back to cohort
Record W3109752579 · doi:10.1017/s1460396920000977

Dosimetric comparison of intensity-modulated radiation therapy (IMRT) and field-in-field (FIF) technique for head-and-neck cancer

2020· article· en· W3109752579 on OpenAlexaff
Nguyen Thi Lan, Hoang Viet, Dương Thanh Tài, James C. L. Chow

Bibliographic record

VenueJournal of Radiotherapy in Practice · 2020
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsPrincess Margaret Cancer CentreUniversity of TorontoUniversity Health Network
Fundersnot available
KeywordsMedicineNuclear medicineDosimetryRadiation therapyRadiation treatment planningHead and neck cancerHead and neckQuality assuranceRadiologySurgery

Abstract

fetched live from OpenAlex

Abstract Purpose: This study compared the plan dosimetry between the intensity-modulated radiation therapy (IMRT) and field-in-field (FIF) technique for head-and-neck cancer using the Elekta Monaco treatment planning system (TPS). Materials and methods: A total of 20 head-and-neck cancer patients were selected in this study. IMRT and FIF plans for the patients were created on the Monaco TPS (ver. 5.11.02) using the 6-MV photon beam generated by the Elekta Synergy linear accelerator. The dose–volume histograms, maximum doses, minimum doses, mean doses of the target volumes and organs-at-risk (OARs), conformity index (CI), homogeneity index (HI) and monitor units (MUs) were determined for each IMRT and FIF plan. All IMRT plans passed the patient-specific quality assurance tests from the 2D diode array measurements (MatriXX Evolution System, IBA Dosimetry, Germany). Results: The results showed that the dose distribution to the target volumes of IMRT plans was better than FIF plans, while the dose (mean or max dose) to the OAR was significantly lower than FIF plan, respectively. IMRT and FIF resulted in planning target volume coverage with mean dose of 71·32 ± 0·76 and 73·12 ± 0·62 Gy, respectively, and HI values of 0·08 ± 0·01 (IMRT) and 0·19 ± 0·06 (FIF). The CI for IMRT was 0·98 ± 0·01 and FIF was 0·97 ± 0·01. For the spinal cord tolerance (maximum dose < 45 Gy), IMRT resulted in 39·85 ± 2·04 Gy compared to 41·37 ± 2·42 Gy for FIF. In addition, the mean doses to the parotid grand were 27·27 ± 7·48 and 48·68 ± 1·62 Gy for the IMRT and FIF plans, respectively. Significantly more MUs were required in IMRT plans than FIF plans (on average, 846 ± 100 MU in IMRT and 467 ± 41 MU in FIF). Conclusions: It is concluded that the IMRT technique could provide a better plan dosimetry than the FIF technique for head-and-neck patients.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.636
Threshold uncertainty score0.617

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.371
Teacher spread0.348 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Radiotherapy in PracticeSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207