MétaCan
Menu
Back to cohort
Record W3111583668 · doi:10.1111/cts.12946

Clinical Evaluation of an Investigational 5 mL Wearable Injector in Healthy Human Subjects

2020· article· en· W3111583668 on OpenAlexaff
Wendy D. Woodley, Yue Wen, Didier Morel, Audrey Lainesse, Ronald J. Pettis, Natasha G. Bolick

Bibliographic record

VenueClinical and Translational Science · 2020
Typearticle
Languageen
FieldMedicine
TopicBotulinum Toxin and Related Neurological Disorders
Canadian institutionsBecton Dickinson (Canada)
Fundersnot available
KeywordsMedicineTolerabilityPlaceboAbdomenErythemaSubcutaneous injectionAnesthesiaSurgeryAdverse effectInternal medicinePathology

Abstract

fetched live from OpenAlex

An investigational wearable injector (WI), the BD Libertas Wearable Injector (BD Libertas is a trademark of Becton, Dickinson and Company), was evaluated in an early feasibility clinical study for functional performance, tissue effects, subject tolerability, and acceptability of 5 mL, non-Newtonian ~ 8 cP subcutaneous placebo injections in 52 healthy adult subjects of 2 age groups (18-64 years and ≥ 65 years). Randomized WI subcutaneous injections (n = 208, 4/subject) were delivered to the right and left abdomen and thigh of each subject, 50% (1 thigh and 1 abdomen) with a defined movement sequence during injection. Injector functional performance was documented. Deposition was qualified and quantified with ultrasound. Tissue effects and tolerability (pain) were monitored through 24 hours with corresponding acceptability questionnaires administered through 72 hours. WI (n = 205) automatically inserted the needle, delivered 5 mL ± 5% in 5.42 minutes (SD 0.74) and retracted. Depots were entirely (93.2%) or predominantly (5.4%) localized within the target subcutaneous tissue. Slight to moderate wheals (63.9%) and erythema (75.1%) were observed with ≥ 50% resolution within 30-60 minutes. Subject pain (100 mm Visual Analog Scale) peaked mid-injection (mean 9.1 mm, SD 13.4) and rapidly resolved within 30 minutes (mean 0.4 mm, SD 2.6). Subjects' peak pain (≥ 90.2%), injection site appearance (≥ 92.2%) and injector wear, size, and removal (≥ 92.1%) were acceptable (Likert responses) with 100% likely to use the injector if prescribed. Injection site preference was divided between none (46%), abdomen (25%), or thigh (26.9%). The investigational WI successfully delivered 5 mL viscous subcutaneous injections. Tissue effects and pain were transient, well-tolerated and acceptable. Neither injection site, movement or subject age affected injector functional performance or subject pain and acceptability.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Non-randomized trial · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.227
GPT teacher head0.459
Teacher spread0.232 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNon-randomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueClinical and Translational ScienceSame topicBotulinum Toxin and Related Neurological DisordersFrench-language works237,207