Microbubble formulation influences inflammatory response to focused ultrasound exposure in the brain

2020· article· en· W3111969895 on OpenAlexaff
Dallan McMahon, Anne Lassus, Emmanuel Gaud, Victor Jeannot, Kullervo Hynynen

Bibliographic record

VenueScientific Reports · 2020
Typearticle
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsUniversity of TorontoSunnybrook Health Science Centre
FundersNational Institute of Biomedical Imaging and Bioengineering
KeywordsMicrobubblesExtravasationBlood–brain barrierProinflammatory cytokinePermeability (electromagnetism)UltrasoundMaterials scienceVascular permeabilityBiophysicsBiomedical engineeringInflammationChemistryMedicinePathologyBiologyImmunologyInternal medicineMembraneCentral nervous system

Abstract

fetched live from OpenAlex

Focused ultrasound and microbubble (FUS + MB)-mediated blood-brain barrier (BBB) permeability enhancement can facilitate targeted brain-drug delivery. While controlling the magnitude of BBB permeability enhancement is necessary to limit tissue damage, little work has attempted to decouple these concepts. This work investigated the relationship between BBB permeability enhancement and the relative transcription of inflammatory mediators 4 h following sonication. Three microbubble formulations, Definity, BG8774, and MSB4, were compared, with the dose of each formulation normalized to gas volume. While changes in the transcription of key proinflammatory mediators, such as Il1b, Ccl2, and Tnf, were correlated to the magnitude of BBB permeability enhancement, these correlations were not independent of microbubble formulation; microbubble size distribution may play an important role, as linear regression analyses of BBB permeability magnitude versus differential gene expression for these proinflammatory mediators revealed significantly greater slopes for MSB4, a monodisperse microbubble with mean diameter of 4 μm, compared to Definity or BG8774, both polydisperse microbubbles with mean diameters below 2 μm. Additionally, the function of an acoustic feedback control algorithm, based on the detection threshold of ultraharmonic emissions, was assessed. While this control strategy was effective in limiting both wideband emissions and red blood cell extravasation, microbubble formulation was found to influence the magnitude of BBB leakage and correlations to acoustic emissions. This work demonstrates that while the initial magnitude of FUS + MB-mediated BBB permeability enhancement has a clear influence on the subsequent inflammatory responses, microbubble characteristics influence these relationships and must also be considered.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.905
Threshold uncertainty score0.328

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.222
Teacher spread0.209 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations49
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueScientific ReportsSame topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207