MétaCan
Menu
Back to cohort
Record W3112018131 · doi:10.5704/moj.2011.012

Patient-reported Outcome Measures of Revision Total Hip Arthroplasty for Prosthetic Joint Infection is not Inferior to Aseptic Revision Total Hip Arthroplasty

2020· article· en· W3112018131 on OpenAlexaboutno aff
Lim Jbt, Pang HN, Tay KJD, Chia SL, Yeo SJ, Lo Nn

Bibliographic record

VenueMalaysian Orthopaedic Journal · 2020
Typearticle
Languageen
FieldMedicine
TopicOrthopedic Infections and Treatments
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineWOMACTotal hip arthroplastySurgeryArthroplastyDemographicsStage (stratigraphy)Aseptic processingOsteoarthritisQuality of life (healthcare)

Abstract

fetched live from OpenAlex

INTRODUCTION: This study aims to investigate whether patients undergoing two-stage revision total hip arthroplasty (THA) for prosthetic joint infection (PJI) and one-stage revision THA for aseptic reasons have similar clinical outcomes and patient satisfaction during their post-operative follow-up. We hypothesise that the two-stage revision THA for PJI is associated with poorer outcomes as compared to aseptic revision THA. MATERIALS AND METHODS: We reviewed prospectively collected data in our tertiary hospital arthroplasty registry and identified patients who underwent revision THA between 2001 and 2014, with a minimum of two years follow-up. The study group (two-stage revision THA for PJI) consists of 23 patients and the control group (one-stage revision THA for aseptic reasons) consists of 231 patients. Patient demographics, Western Ontario and McMaster Universities Arthritis Index (WOMAC), Oxford Hip Score (OHS), Short Form-36 (SF-36) scores and patient reported satisfaction were evaluated. Student's t-test was used to compare continuous variables between the two groups. Statistical significance was defined as p <0.05. RESULTS: The pre-operative demographics and clinical scores were relatively similar between the two groups of patients. At two years, patients who underwent revision THA for PJI reported a better WOMAC Pain Score and OHS as compared to aseptic revision THA. A similar proportion of patients were satisfied with their results of surgery in both groups (p=0.093). CONCLUSIONS: Although patients who underwent revision THA for PJI had poorer pre-operative functional scores (WOMAC function and SF-36 PF), at two years follow-up, these two groups of patients have comparable post-operative outcomes. Interestingly, patients who had revision THA for PJI reported a better clinical outcome in terms of OHS and WOMAC Pain score as compared to the aseptic group. We conclude that the revision THA for PJI is not inferior to aseptic revision THA in terms of patient satisfaction and clinical outcomes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.450
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.047
GPT teacher head0.288
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueMalaysian Orthopaedic JournalSame topicOrthopedic Infections and TreatmentsFrench-language works237,207