MétaCan
Menu
Back to cohort
Record W3112084732 · doi:10.22374/jclrs.v4i1.39

Clinical Performance of a Novel Daily Disposable Soft Contact Lens

2020· article· en· W3112084732 on OpenAlexvenueno aff
Stacie Cummings, Bradley Giedd, Christopher Pearson

Bibliographic record

VenueJournal of Contact lens Research and Science · 2020
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsnot available
Fundersnot available
KeywordsContact lensMedicineVisual acuityOptometryDiscontinuationDioptreGLARERefractive errorOphthalmologySubjective refractionSurgery

Abstract

fetched live from OpenAlex

Background and Objective: Verofilcon A (PRECISION1®; Alcon) silicone hydrogel daily disposable contact lenses were designed to address clinical issues associated with new wearer discontinuation, including vision quality, sustained comfort, and ease of handling. The present study assessed the objective and subjective performance of verofilcon A contact lenses in subjects needing optical correction for refractive ametropia.
 Material and Methods: Subjects aged 18 years and older with non-diseased eyes, a history of successful soft contact lens wear for distance correction in both eyes during the previous 3 months, and a best spectacle-corrected visual acuity of 20/25 or better with a manifest cylinder of ≤ 0.75 diopters in each eye were recruited. The primary endpoint was distance visual acuity. Secondary endpoints included subjective ratings of overall vision, comfort, and handling, and safety endpoints included adverse events and biomicroscopy/slit lamp examination findings.
 Results: This study recruited 70 subjects (140 eyes), aged 20–48 years, who were predominantly white (93%), non-Hispanic/Latino (94%), and female (73%); one subject discontinued due to a change in residence. Of the 140 eyes, 132 (94.3%) had 20/20 or better vision with their habitual contact lenses. Similarly, of the 138 eyes that completed the study, 136 (98.6%) had 20/20 or better vision at dispensation of verofilcon A lenses and 132 (95.7%) had 20/20 or better vision at 3 months. Mean ± SD subjective ratings of overall vision, overall comfort, and overall handling, each on a 10-point scale, were 9.4 ± 0.8, 9.4 ± 0.8, and 9.2 ± 1.3, respectively, at lens dispensing, and 9.4 ± 0.9, 9.5 ± 0.8, and 9.2 ± 1.0, respectively, at 3 months. Mean ± SD daily wear times at 1 week and 3 months were 14.71 ± 1.85 and 15.05 ± 1.27 hours, respectively, with 68.1% at 1 week and 73.9% at 3 months wearing verofilcon A lenses for 14–18 hours per day. None of the subjects experienced a serious adverse event or discontinued lens wear, with biomicroscopy/slit lamp examination showing no evidence of corneal edema or chemosis.
 Conclusion: Subjects wearing verofilcon A lenses had visual acuity similar to that when wearing their habitual lens. Verofilcon A lenses were highly rated for vision quality, comfort, and handling. Verofilcon A lenses may be an option for subjects with refractive ametropia who desire lenses that can be worn for >14 hours per day and are easy to handle.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.407
Threshold uncertainty score0.487

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0040.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.146
GPT teacher head0.408
Teacher spread0.262 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Contact lens Research and ScienceSame topicOcular Surface and Contact LensFrench-language works237,207