MétaCan
Menu
Back to cohort
Record W3113224983 · doi:10.29390/cjrt-2020-033

In vitro investigation of the Flusso™ Bypass adapter efficiency upon ventilator circuit disconnect in a clinical simulated environment

2020· article· en· W3113224983 on OpenAlexaffvenue
Rym Mehri, Abubakar Alatrash, Edgar Matida, Frank Fiorenza

Bibliographic record

VenueCanadian Journal of Respiratory Therapy · 2020
Typearticle
Languageen
FieldMedicine
TopicRespiratory Support and Mechanisms
Canadian institutionsUniversity of OttawaCarleton University
Fundersnot available
KeywordsExhalationAdapter (computing)Mechanical ventilatorALARMEnvironmental scienceAnesthesiaComputer scienceMedicineMechanical ventilationElectrical engineeringEngineeringComputer hardware

Abstract

fetched live from OpenAlex

RATIONALE: Mechanically ventilated patients must be disconnected from the ventilator during intra-facility transfers. Intentional and accidental circuit disconnections represent a potential hazard to patients (sudden collapse and re-expansion of the alveoli) as well as to clinical staff (exposure to patient's unfiltered exhalation). Therefore, avoiding abrupt circuit disconnections could better protect the patient's health and reduce or eliminate contamination risks around clinical staff. OBJECTIVE: The purpose of this in-vitro work was to investigate and evaluate the potential for environmental exposure of Nitric Oxide (NO, as an indicator of any contamination exposure) before and after implementing the novel Flusso™ Bypass adapter during the disconnect procedure of a mechanical ventilator system. METHODS: A mechanical ventilator delivering NO was connected to a breathing simulator with and without the Flusso™ Bypass adapter. The ambient NO concentration was measured when the circuit was briefly disconnected (3 s) during inhalation and exhalation. Both volume and pressure ventilation modes were used. MEASUREMENTS AND MAIN RESULTS: Disconnecting the standard ventilator circuit (pressure-controlled mode) without the Flusso™ Bypass adapter produced higher NO escape to the surroundings (compared with the volume-controlled mode), leading to a longer NO dissipation time. No ambient NO traces were detected when the Flusso™ adapter was used. CONCLUSION: The usage of the Flusso™ adapter drastically decreases the unwanted exposure among clinical staff dealing with potentially hazardous airborne biological aerosols emanating from the circuit. Avoiding abrupt disconnection in the ventilator circuit could reduce lung injuries and alveolar over distension and collapse.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.071
GPT teacher head0.282
Teacher spread0.211 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueCanadian Journal of Respiratory TherapySame topicRespiratory Support and MechanismsFrench-language works237,207