MétaCan
Menu
Back to cohort
Record W3118205311 · doi:10.1111/jvim.15983

Accuracy of point-of-care crossmatching methods and crossmatch incompatibility in critically ill dogs

2020· article· en· W3118205311 on OpenAlexafffund
Hayden A. Marshall, Shauna L. Blois, Anthony C. G. Abrams‐Ogg, Alexa M. Bersenas, Kristiina Ruotsalo, Gabrielle Monteith

Bibliographic record

VenueJournal of Veterinary Internal Medicine · 2020
Typearticle
Languageen
FieldMedicine
TopicBlood transfusion and management
Canadian institutionsUniversity of Guelph
FundersOVC Pet Trust
KeywordsMedicinePoint of carePoint-of-care testingConfidence intervalCritically illMedical recordAgglutination (biology)Emergency medicineSurgeryInternal medicinePathologyImmunology

Abstract

fetched live from OpenAlex

BACKGROUND: The performance of commercial point-of-care crossmatch (CM) tests compared to laboratory tube agglutination CM is unknown. Additionally, there is limited information regarding CM incompatibility in ill dogs. OBJECTIVES: To determine if point-of-care major CM methods are accurate in detecting compatible and incompatible tests when compared to laboratory CM methods, and to identify factors associated with CM incompatibility in dogs. ANIMALS: Part 1 (prospective) included 63 client-owned dogs potentially requiring blood transfusion. Part 2 (retrospective) included all dogs from part 1, plus medical records of 141 dogs with major CM results. METHODS: For part 1, major CM was performed using a tube agglutination assay (LAB-CM), a gel-based point-of-care test (GEL-CM), and an immunochromatographic point-of-care test (IC-CM). For part 2, medical record data were collected to determine rates of and risk factors for CM incompatibility. RESULTS: Kappa agreement between the LAB-CM and GEL-CM methods could not be calculated due to a relative lack of incompatible results. Kappa agreement between the LAB-CM and IC-CM methods was 0.16 (95% confidence interval [CI] = 0-0.31, P = .007) indicating no agreement. The LAB-CM incompatibility in transfusion-naïve vs dogs that had a transfusion was 25% and 35%, (P = .3). CONCLUSIONS AND CLINICAL IMPORTANCE: Compared to laboratory methods, point-of-care methods evaluated in our study lacked sensitivity for detecting incompatibilities. Dogs had similar rates of major CM incompatibility regardless of transfusion history. This suggests CM testing prior to transfusion be considered in all dogs however our study did not investigate clinical relevancy of incompatible LAB-CM.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.037
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.032

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.037
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.056
GPT teacher head0.424
Teacher spread0.368 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Veterinary Internal MedicineSame topicBlood transfusion and managementFrench-language works237,207