MétaCan
Menu
Back to cohort
Record W3120807406 · doi:10.3233/adr-200242

Shining the Light on the MotionWatch8 Light Sensor for Sleep and Aging Research: What Can We Measure and What Are We Missing?

2021· article· en· W3120807406 on OpenAlexafffund
Ryan S. Falck, Rachel A. Crockett, Jennifer C. Davis, Karim M. Khan, Teresa Liu‐Ambrose

Bibliographic record

VenueJournal of Alzheimer s Disease Reports · 2021
Typearticle
Languageen
FieldPsychology
TopicSleep and related disorders
Canadian institutionsOkanagan University CollegeUniversity of British Columbia, Okanagan CampusUniversity of British Columbia
FundersInstitute of Musculoskeletal Health and ArthritisCanadian Institutes of Health ResearchUniversity of British Columbia
KeywordsMeasure (data warehouse)Sleep (system call)Computer sciencePsychologyData mining

Abstract

fetched live from OpenAlex

BACKGROUND: Poor sleep is common among older adults at risk for dementia and may be due to circadian dysregulation. Light is the most important external stimulus to the circadian clock and bright light therapy (BLT) has been used for >20 years to help realign circadian rhythms. However, the ability of field methods (e.g., actigraphy) to accurately determine the type and intensity of light is unknown. OBJECTIVE: We examined the ability of the MotionWatch8 (MW8) light sensor to determine: 1) light versus dark, 2) electrical light versus daylight, and 3) device-based BLT versus light which was not BLT. METHODS: We tested the MW8 under 17 daily light scenarios. Light exposure data was collected for 5 minutes during each scenario. Concurrently, we measured light exposure using the LT40 Light Meter, a sensitive measure of light intensity. We then developed individual cut-points using receiver operator characteristics analyses to determine optimal MW8 cut-points for 1) light versus dark; 2) electrical light versus daylight; and 3) light from a BLT box versus light which was not BLT. Bland-Altman plots tested the precision of the MW8 compared to the LT40. RESULTS: The MW8 accurately discriminated light versus dark (>32 lux), and electrical light versus daylight (<323 lux). However, the MW8 had poor accuracy for 1) discriminating BLT from light which was not BLT; and 2) low precision compared to the LT40. CONCLUSION: The MW8 appears to be able to discern light versus dark and electrical light versus daylight; however, there remains a need for accurate field methods capable of measuring light exposure.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.015
metaresearch head score (Gemma)0.025
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.015
Threshold uncertainty score0.080

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0150.025
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0020.002
Bibliometrics0.0020.001
Science and technology studies0.0010.002
Scholarly communication0.0030.004
Open science0.0020.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0030.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.079
GPT teacher head0.342
Teacher spread0.263 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Alzheimer s Disease ReportsSame topicSleep and related disordersFrench-language works237,207