MétaCan
Menu
Back to cohort

Semi-automatic Algorithms for Estimation and Tracking of AP-diameter of the IVC in Ultrasound Images

2018· preprint· en· W3123080363 on OpenAlexaff
Ebrahim Karami, Mohamed Shehata, Andrew Smith

Bibliographic record

VenuePreprints.org · 2018
Typepreprint
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsMemorial University of Newfoundland
Fundersnot available
KeywordsEllipseRectangleUltrasoundInferior vena cavaTracking (education)AlgorithmArtificial intelligenceComputer scienceComputer visionMedicineMathematicsRadiologyGeometry

Abstract

fetched live from OpenAlex

Medical research has suggested that the anterior-posterior (AP)-diameter of the inferior vena cava (IVC) and its associated temporal variation as imaged by bedside ultrasound is useful in guiding fluid resuscitation of the critically-ill patients. This paper develops semi-automatic active ellipse and rectangle algorithms for measurement and tracking of the AP-diameter. The proposed algorithms are compared with an expert manual measurement and the previous work based on active circle model. It is shown that regardless of the shape of the IVC, the rectangle model always outperforms the two other models and performs very close to manual measurement.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.007
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.002
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.007
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.094
GPT teacher head0.380
Teacher spread0.287 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2018
Admission routes1
Has abstractyes

Explore more

Same venuePreprints.orgSame topicHemodynamic Monitoring and TherapyFrench-language works237,207