MétaCan
Menu
Back to cohort
Record W3123202920 · doi:10.1111/jocs.15351

Simultaneous transaortic transcatheter aortic valve implantation and off‐pump coronary artery bypass: An effective hybrid approach

2021· article· en· W3123202920 on OpenAlexaboutno aff
Alina Zubarevich, Konstantin Zhigalov, Marcin Szczechowicz, Matthias Thielmann, Marco Rabis, Jef Van den Eynde, Michel Pompeu Sá, Wilko Weißenberger, Bakytbek Kadyraliev, S. Т. Enginoev, Rolf Alexander Jánosi, Alexander Lind, Tienush Rassaf, Bastian Schmack, Arjang Ruhparwar, Alexander Weymann, Daniel Wendt

Bibliographic record

VenueJournal of Cardiac Surgery · 2021
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineCardiologyInternal medicineInterquartile rangeStroke (engine)EuroSCOREMyocardial infarctionAnginaStenosisCoronary artery diseaseRevascularizationCanadian Cardiovascular SocietySurgeryAortic valve replacementArtery

Abstract

fetched live from OpenAlex

INTRODUCTION: Transcatheter aortic valve implantation (TAVI) techniques are increasingly being adopted into clinical routine for various risk groups. Coronary artery disease (CAD) is seen in up to 75% of patients with severe aortic valve stenosis (AS) presenting with typical angina pectoris. Due to high mortality rates and procedural complications in these patients, a hybrid concept of simultaneous transaortic TAVI and off-pump coronary artery bypass (OPCAB) can be a feasible treatment option. METHODS: Between April 2014 and July 2020, 10 consecutive high-risk patients underwent concomitant transaortic TAVI and OPCAB at our institution. All indications were discussed in Heart Team and decisions were made based on patients' comorbidities and complexity of CAD. The study endpoints were 30-day mortality, device success, and development of postoperative adverse events defined by the Valve Academic Research Consorium. RESULTS: The mean age of the patients was 77.9 ± 7.1 years old. All patients presented with multiple comorbidities (mean logistic EuroSCORE 26.5 ± 12.3%, median EuroSCORE II 5.13% [interquartile range 4.2-9.5], mean STS-Score 6.04 ± 1.6%). Five patients (50%) presented with porcelain aorta. No conversion to conventional procedures was needed. 30-day mortality occurred in one patient (10%). Complete revascularization was achieved in seven (70%) of the patients. Device success rate was 100%. No paravalvular leakage was detected. No stroke, myocardial infarction or vascular complications were observed. CONCLUSIONS: A hybrid approach combining transaortic TAVI and OPCAB might be a safe and feasible method of treatment in high-risk patients presenting with severe AS and CAD who are not eligible for conventional surgical or interventional solutions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.467
Threshold uncertainty score0.852

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.004
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.281
Teacher spread0.271 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Cardiac SurgerySame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207