MétaCan
Menu
Back to cohort
Record W3123567368 · doi:10.1063/5.0014329

2D monochromatic x-ray imaging for beam monitoring of an x-ray free electron laser and a high-power femtosecond laser

2021· article· en· W3123567368 on OpenAlexafffund
Hiroshi Sawada, Jacob Trzaska, C. B. Curry, M. Gauthier, L. B. Fletcher, S. Jiang, Hae Ja Lee, Eric Galtier, Eric Cunningham, G. Dyer, Tyler Daykin, L. Chen, Christopher M. Salinas, G. D. Glenn, Mungo Frost, S. H. Glenzer, Y. Ping, A. Kemp, Y. Sentoku

Bibliographic record

VenueReview of Scientific Instruments · 2021
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced X-ray Imaging Techniques
Canadian institutionsUniversity of Alberta
FundersSLAC National Accelerator LaboratoryLawrence Livermore National LaboratoryWorkforce Development for Teachers and ScientistsBasic Energy SciencesNatural Sciences and Engineering Research Council of CanadaNational Science FoundationMinisterio de Economía y CompetitividadFusion Energy SciencesU.S. Department of EnergyOffice of Science
KeywordsLaserOpticsLaser beam qualityFemtosecondBeam (structure)Monochromatic colorBeam parameter productX-ray laserPhysicsMaterials scienceLaser power scalingLaser beams

Abstract

fetched live from OpenAlex

In pump-probe experiments with an X-ray Free Electron Laser (XFEL) and a high-power optical laser, spatial overlap of the two beams must be ensured to probe a pumped area with the x-ray beam. A beam monitoring diagnostic is particularly important in short-pulse laser experiments where a tightly focused beam is required to achieve a relativistic laser intensity for generation of energetic particles. Here, we report the demonstration of on-shot beam pointing measurements of an XFEL and a terawatt class femtosecond laser using 2D monochromatic Kα imaging at the Matter in Extreme Conditions end-station of the Linac Coherent Light Source. A thin solid titanium foil was irradiated by a 25-TW laser for fast electron isochoric heating, while a 7.0 keV XFEL beam was used to probe the laser-heated region. Using a spherical crystal imager (SCI), the beam overlap was examined by measuring 4.51 keV Kα x rays produced by laser-accelerated fast electrons and the x-ray beam. Measurements were made for XFEL-only at various focus lens positions, laser-only, and two-beam shots. Successful beam overlapping was observed on ∼58% of all two-beam shots for 10 μm thick samples. It is found that large spatial offsets of laser-induced Kα spots are attributed to imprecise target positioning rather than shot-to-shot laser pointing variations. By applying the Kα measurements to x-ray Thomson scattering measurements, we found an optimum x-ray beam spot size that maximizes scattering signals. Monochromatic x-ray imaging with the SCI could be used as an on-shot beam pointing monitor for XFEL-laser or multiple short-pulse laser experiments.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.591
Threshold uncertainty score0.855

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.283
Teacher spread0.273 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueReview of Scientific InstrumentsSame topicAdvanced X-ray Imaging TechniquesFrench-language works237,207