MétaCan
Menu
Back to cohort
Record W3127268931 · doi:10.1093/ehjci/jeaa356.434

Assessing automated CMR contouring algorithms using systematic contour quality scoring analysis

2021· article· en· W3127268931 on OpenAlexaff
Muhammad Omer, Alborz Amir-Khalili, Alireza Sojoudi, Thu Thao Le, Stephane Cook, Desiree‐Faye Toh, Jennifer Bryant, Calvin Chin, José Miguel Paiva, Ko Fung, Nyi Nyein Aung, M Y Khanji, Elisa Rauseo, Jason Cooper, Steffen E. Petersen

Bibliographic record

VenueEuropean Heart Journal - Cardiovascular Imaging · 2021
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsCircle Cardiovascular Imaging
Fundersnot available
KeywordsContouringArtificial intelligenceComputer scienceHausdorff distanceSegmentationSimilarity (geometry)MedicineMachine learningAlgorithmComputer visionImage (mathematics)Computer graphics (images)

Abstract

fetched live from OpenAlex

Abstract Funding Acknowledgements Type of funding sources: Public grant(s) – National budget only. Main funding source(s): SmartHeart EPSRC programme grant (www.nihr.ac.uk), London Medical Imaging and AI Centre for Value-Based Healthcare Background Quality measures for machine learning algorithms include clinical measures such as end-diastolic (ED) and end-systolic (ES) volume, volumetric overlaps such as Dice similarity coefficient and surface distances such as Hausdorff distance. These measures capture differences between manually drawn and automated contours but fail to capture the trust of a clinician to an automatically generated contour. Purpose We propose to directly capture clinicians’ trust in a systematic way. We display manual and automated contours sequentially in random order and ask the clinicians to score the contour quality. We then perform statistical analysis for both sources of contours and stratify results based on contour type. Data The data selected for this experiment came from the National Health Center Singapore. It constitutes CMR scans from 313 patients with diverse pathologies including: healthy, dilated cardiomyopathy (DCM), hypertension (HTN), hypertrophic cardiomyopathy (HCM), ischemic heart disease (IHD), left ventricular non-compaction (LVNC), and myocarditis. Each study contains a short axis (SAX) stack, with ED and ES phases manually annotated. Automated contours are generated for each SAX image for which manual annotation is available. For this, a machine learning algorithm trained at Circle Cardiovascular Imaging Inc. is applied and the resulting predictions are saved to be displayed in the contour quality scoring (CQS) application. Methods: The CQS application displays manual and automated contours in a random order and presents the user an option to assign a contour quality score 1: Unacceptable, 2: Bad, 3: Fair, 4: Good. The UK Biobank standard operating procedure is used for assessing the quality of the contoured images. Quality scores are assigned based on how the contour affects clinical outcomes. However, as images are presented independent of spatiotemporal context, contour quality is assessed based on how well the area of the delineated structure is approximated. Consequently, small contours and small deviations are rarely assigned a quality score of less than 2, as they are not clinically relevant. Special attention is given to the RV-endo contours as often, mostly in basal images, two separate contours appear. In such cases, a score of 3 is given if the two disjoint contours sufficiently encompass the underlying anatomy; otherwise they are scored as 2 or 1. Results A total of 50991 quality scores (24208 manual and 26783 automated) are generated by five expert raters. The mean score for all manual and automated contours are 3.77 ± 0.48 and 3.77 ± 0.52, respectively. The breakdown of mean quality scores by contour type is included in Fig. 1a while the distribution of quality scores for various raters are shown in Fig. 1b. Conclusion We proposed a method of comparing the quality of manual versus automated contouring methods. Results suggest similar statistics in quality scores for both sources of contours. Abstract Figure 1

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.020
metaresearch head score (Gemma)0.077
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.020
Threshold uncertainty score0.107

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0200.077
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0040.001
Science and technology studies0.0000.001
Scholarly communication0.0020.001
Open science0.0010.002
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.076
GPT teacher head0.370
Teacher spread0.294 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Heart Journal - Cardiovascular ImagingSame topicCardiac Imaging and DiagnosticsFrench-language works237,207