MétaCan
Menu
Back to cohort
Record W3128409362 · doi:10.1667/rade-20-00212.1

Fluoroscopy X-Ray Organ-Specific Dosimetry System (FLUXOR) for Estimation of Organ Doses and Their Uncertainties in the Canadian Fluoroscopy Cohort Study

2021· article· en· W3128409362 on OpenAlexaboutno aff
A. Iulian Apostoaei, Brian A. Thomas, F.O. Hoffman, D.C. Kocher, Kathleen M. Thiessen, David Borrego, Choonsik Lee, Steven L. Simon, Lydia B. Zablotska

Bibliographic record

VenueRadiation Research · 2021
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsnot available
FundersNational Cancer InstituteNational Institutes of HealthUniversity of California, San FranciscoUniversity of Southern California
KeywordsFluoroscopyMedicineDosimetryCohortRadiographyRadiologyNuclear medicineInternal medicine

Abstract

fetched live from OpenAlex

As part of ongoing efforts to assess lifespan disease mortality and incidence in 63,715 patients from the Canadian Fluoroscopy Cohort Study (CFCS) who were treated for tuberculosis between 1930 and 1969, we developed a new FLUoroscopy X-ray ORgan-specific dosimetry system (FLUXOR) to estimate radiation doses to various organs and tissues. Approximately 45% of patients received medical procedures accompanied by fluoroscopy, including artificial pneumothorax (air in pleural cavity to collapse of lungs), pneumoperitoneum (air in peritoneal cavity), aspiration of fluid from pleural cavity and gastrointestinal series. In addition, patients received chest radiographs for purposes of diagnosis and monitoring of disease status. FLUXOR utilizes age-, sex- and body size-dependent dose coefficients for fluoroscopy and radiography exams, estimated using radiation transport simulations in up-to-date computational hybrid anthropomorphic phantoms. The phantoms include an updated heart model, and were adjusted to match the estimated mean height and body mass of tuberculosis patients in Canada during the relevant time period. Patient-specific data (machine settings, exposure duration, patient orientation) used during individual fluoroscopy or radiography exams were not recorded. Doses to patients were based on parameter values inferred from interviews with 91 physicians practicing at the time, historical literature, and estimated number of procedures from patient records. FLUXOR uses probability distributions to represent the uncertainty in the unknown true, average value of each dosimetry parameter. Uncertainties were shared across all patients within specific subgroups of the cohort, defined by age at treatment, sex, type of procedure, time period of exams and region (Nova Scotia or other provinces). Monte Carlo techniques were used to propagate uncertainties, by sampling alternative average values for each parameter. Alternative average doses per exam were estimated for patients in each subgroup, with the total average dose per individual determined by the number of exams received. This process was repeated to produce alternative cohort vectors of average organ doses per patient. This article presents estimates of doses to lungs, female breast, active bone marrow and heart wall. Means and 95% confidence intervals (CI) of average organ doses across all 63,715 patients were 320 (160, 560) mGy to lungs, 250 (120, 450) mGy to female breast, 190 (100, 340) mGy to heart wall and 92 (47, 160) mGy to active bone marrow. Approximately 60% of all patients had average doses to the four studied organs of less than 10 mGy, 10% received between 10 and 100 mGy, 25% between 100 and 1,000 mGy, and 5% above 1,000 mGy. Pneumothorax was the medical procedure that accounted for the largest contribution to cohort average doses. The major contributors to uncertainty in estimated doses per procedure for the four organs of interest are the uncertainties in exposure duration, tube voltage, tube output, and patient orientation relative to the X-ray tube, with the uncertainty in exposure duration being most often the dominant source. Uncertainty in patient orientation was important for doses to female breast, and, to a lesser degree, for doses to heart wall. The uncertainty in number of exams was an important contributor to uncertainty for ∼30% of patients. The estimated organ doses and their uncertainties will be used for analyses of incidence and mortality of cancer and non-cancer diseases. The CFCS cohort is an important addition to existing radio-epidemiological cohorts, given the moderate-to-high doses received fractionated over several years, the type of irradiation (external irradiation only), radiation type (X rays only), a balanced combination of both genders and inclusion of people of all ages.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.008
metaresearch head score (Gemma)0.013
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.091
Threshold uncertainty score0.184

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0080.013
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.003
Science and technology studies0.0010.000
Scholarly communication0.0010.000
Open science0.0020.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.042
GPT teacher head0.364
Teacher spread0.322 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueRadiation ResearchSame topicRadiation Dose and ImagingFrench-language works237,207