MétaCan
Menu
Back to cohort
Record W3130221774 · doi:10.1002/mrm.28715

Improving the sensitivity of spin‐echo fMRI at 3T by highly accelerated acquisitions

2021· article· en· W3130221774 on OpenAlexaff
Antonia Barghoorn, Bruno Riemenschneider, Jürgen Hennig, Pierre LeVan

Bibliographic record

VenueMagnetic Resonance in Medicine · 2021
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsAlberta Children's HospitalUniversity of Calgary
FundersBundesministerium für Bildung und ForschungDeutsche Forschungsgemeinschaft
KeywordsResting state fMRIEcho timeNuclear magnetic resonanceSpin echoFunctional magnetic resonance imagingPulse sequenceSensitivity (control systems)MultisliceGradient echoPulse (music)Magnetic resonance imagingBlood oxygenationPhysicsNeuroscienceMedicineOpticsPsychology

Abstract

fetched live from OpenAlex

PURPOSE: -weighted GE sequences because of their superior sensitivity compared to SE-fMRI. The presented SE implementation of a highly accelerated GE pulse sequence therefore aims to improve the sensitivity of SE-fMRI while profiting from a reduction of susceptibility-induced signal dropout. METHODS: Spin-echo MR encephalography (SE-MREG) is compared with the more conventionally used spin-echo echo-planar imaging (SE-EPI) and spin-echo simultaneous multislice (SE-SMS) at 3T in terms of capability to detect neuronal activations and resting-state functional connectivity. For activation analysis, healthy subjects underwent consecutive SE-MREG (pulse repetition time [TR] = 0.25 seconds), SE-SMS (TR = 1.3 seconds), and SE-EPI (TR = 4.4 seconds) scans in pseudorandomized order applied to a visual block design paradigm for generation of t-statistics maps. For the investigation of functional connectivity, additional resting-state data were acquired for 5 minutes and a seed-based correlation analysis using Stanford's FIND (Functional Imaging in Neuropsychiatric Disorders) atlas was performed. RESULTS: The increased sampling rate of SE-MREG relative to SE-SMS and SE-EPI improves the sensitivity to detect BOLD activation by 33% and 54%, respectively, and increases the capability to extract resting-state networks. Compared with a brain region that is not affected by magnetic field inhomogeneities, SE-MREG shows 2.5 times higher relative signal strength than GE-MREG in mesial temporal structures. CONCLUSION: SE-MREG offers a viable possibility for whole-brain fMRI with consideration of brain regions that are affected by strong susceptibility-induced magnetic field gradients.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.004
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.311
Teacher spread0.291 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207