Canadian Registry of Electronic Device Outcomes: remote monitoring outcomes in the Abbott battery performance alert—a multicentre cohort

2021· article· en· W3132286763 on OpenAlexafffundabout
Sharath Kumar, Jason Davis, Bernard Thibault, Iqwal Mangat, Benoit Coutu, Matthew T. Bennett, François Philippon, Roopinder K. Sandhu, Laurence D. Sterns, Vidal Essebag, Pablo B. Nery, George A. Wells, Raymond Yee, Derek V. Exner, Andrew D. Krahn, Ratika Parkash

Bibliographic record

VenueEP Europace · 2021
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsLondon Health Sciences CentreLibin Cardiovascular Institute of AlbertaUniversity Health NetworkMcGill UniversityUniversity of OttawaRoyal Jubilee HospitalMontreal Heart InstituteUniversity of British ColumbiaUniversité LavalCentre Hospitalier de l’Université de MontréalSt. Michael's HospitalUniversity of Alberta
FundersAbbott Canada
KeywordsMedicineCardiac resynchronization therapyCohortBattery (electricity)Emergency medicineMedical emergencyInternal medicineHeart failureEjection fraction

Abstract

fetched live from OpenAlex

AIMS: Cardiac implantable electronic devices with device advisories have the potential of device malfunction. Remote monitoring (RM) of devices has been suggested to allow the identification of abnormal device performance and permit early intervention. We sought to describe the outcomes of patients with and without RM in devices subject to the Abbott Premature Battery Depletion (PBD) advisory with data from a Canadian registry. METHODS AND RESULTS: Patients with an Abbott device subject to the PBD advisory from nine implantable cardioverter defibrillator (ICD) implanting centres in Canada were included in the registry. The use of RM was identified from baseline and follow-up data in the registry. The primary outcome was detection of PBD and all-cause mortality. A total of 2666 patients were identified with a device subject to the advisory. In all, 1687 patients (63.2%) had RM at baseline. There were 487 deaths during follow-up. At a mean follow-up of 5.7 ± 0.7 years, mortality was higher in those without a remote monitor compared with RM at baseline (24.7% vs. 14.5%; P < 0.001). Pre-mature battery depletion was identified in 36 patients (2.1%) with RM vs. 7 (0.7%) without RM (P = 0.004). Time to battery replacement was significantly reduced in patients on RM (median 5 vs. 13 days, P = 0.001). CONCLUSION: The use of RM in patients with ICD and cardiac resynchronization therapy under advisory improved detection of PBD, time to device replacement, and was associated with a reduction in all-cause mortality. The factors influencing the association with mortality are unknown and deserve further study.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.912
Threshold uncertainty score0.176

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.004
Science and technology studies0.0020.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.287
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2021
Admission routes3
Has abstractyes

Explore more

Same venueEP EuropaceSame topicCardiac pacing and defibrillation studiesFrench-language works237,207